ACTpro DESFIRE EV1 Operating and Installation Manual
Rev 1.0
Wiring Information for “Wiegand” Output
The standard Wiegand wiring colours for ACTpro MIFARE DESFire EV1 readers are shown below.
Reader PIN Description
Recommended wiring colour
Description
Sense
White
Direction – connect for entry
Clock / D1
Green
Clock / D1
Data / D0
Blue
Data / D0
12-24 V DC
Red
+ Voltage
0 V
Black
- Voltage
Red
Brown
Red LED
Green
Yellow
Green LED
Wiring for Entry / Exit “Wiegand” Readers
Wiring for “Wiegand” Entry Reader
Colour
Controller Pin
White 0V
Green
CLOCK / D1
Blue DATA
/
D0
Red +12V
Black 0V
Brown RED
Yellow GREEN
Wiring for “Wiegand” Exit Reader
Colour
Controller Pin
White 0V
Green
CLOCK / D1
Blue Sense
Red +12V
Black 0V
Brown RED
Yellow GREEN
3