background image

www.acti.com

USER’S MANUAL 

 

Wiring 

Terminal Description   

Group 

No. 

Function 

Color 

Name 

Description 

Group A 

A1 

Power Input 

Red 

+12 V 

12 VDC Power 

Supply 

A2 

Black 

GND 

Ground 

Group B 

B1 

RS-485 

Yellow 

485+ 

RS-485 Wiring 

B2 

Blue 

485- 

B3 

Red/Black 

GND 

Ground 

Group C 

C1 

Wiegand 

Green 

W0 

Wiegand Wiring 

C2 

White 

W1 

Wiegand Wiring 

C3 

White/Black 

GND 

Ground 

Group D 

D1 

Door Lock 

White/Purple  NC 

Lock Wiring (NC) 

D2 

White/Yellow  COM 

Common 

D3 

White/Red 

NO 

Lock Wiring (NO) 

D4 

Yellow/Gree

SENSOR 

Door Contact 

D5 

Black 

GND 

Ground 

D6 

Yellow/Gray 

BUTTON 

Exit Door Wiring 

D7 

Yellow/Black 

GND 

Ground 

Summary of Contents for R71CF-38

Page 1: ...Face Recognition Reader Controller User s Manual R71CF 38 2021 03 24...

Page 2: ...to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorien...

Page 3: ...cycling return this product to your local supplier upon the purchase of equivalent new equipment or dispose of it at designated collection points For more information see www recyclethis info 2006 66...

Page 4: ...the product is installed on wall or ceiling the device shall be firmly fixed If smoke odors or noise rise from the device turn off the power at once and unplug the power cable and then please contact...

Page 5: ...over avoid direct contact with the device cover because the acidic sweat of the fingers may erode the surface coating of the device cover Please use a soft and dry cloth when clean inside and outside...

Page 6: ...Wiring 9 Terminal Description 9 Wiring Common Devices 10 Wiring Secure Door Control Unit 10 Installation 11 Installation Environment 11 Installation Height 11 Wall Mounting 12 Initial Settings 14 Step...

Page 7: ...ER S MANUAL 7 Introduction Package Content Face Recognition Reader Controller Mounting plate Wrench Lock screws for mounting plate x2 Screw pack Cable Mini USB to USB cable converter Quick start guide...

Page 8: ...cti com USER S MANUAL 8 Physical Description Item 1 Camera 2 IR LED 3 Touch Screen 4 Card Reader 5 USB connector 6 Speaker 7 Tamper Key 8 Terminal Cable Connector 9 Ethernet 10 Debugging for debugging...

Page 9: ...low 485 RS 485 Wiring B2 Blue 485 B3 Red Black GND Ground Group C C1 Wiegand Green W0 Wiegand Wiring 0 C2 White W1 Wiegand Wiring 1 C3 White Black GND Ground Group D D1 Door Lock White Purple NC Lock...

Page 10: ...ing to an access controller set the device Wiegand direction as Output to transmit authentication information to the access controller Do not wire the device to the electric supply directly Wiring Sec...

Page 11: ...direct sunlight Avoid direct or indirect sunlight through window The device should be installed at least 2 meters away from light and 3 meters away from the window or door Make sure the wall can bear...

Page 12: ...surface where the device will be installed according to the bundled Drill Template 2 Align the holes to the mounting plate and secure it to the wall using the 4 supplied screws 3 Route the cable thro...

Page 13: ...www acti com USER S MANUAL 13 4 Attach one of the supplied lock screw to secure the device and the mounting plate...

Page 14: ...onfigured first Step 1 Login 1 Long tap the screen for 3 seconds a gesture icon will appear then slide to the left or right to enter the Login page 2 Tap the unlock icon for the device to prompt for t...

Page 15: ...Mask and Gateway Enable DHCP the system will assign IP address subnet mask and gateway automatically Disable DHCP you will need to manually set the IP address subnet mask and gateway NOTE The device...

Page 16: ...part a shortcut for QR Code scanning is shown This function is available for purchase contact your system integrator for details Home Menu After login the Home Menu appears Below is the summary of th...

Page 17: ...menu allows you to set the Wired Network Wi Fi RS 485 and Wiegand parameters Basic The Basic Settings menu allows you to set the voice time language and other general device settings Biometrics The B...

Page 18: ...ensure recognition accuracy Registering a face can be done through the Access Control Server see Access Control Server manual for more details Expression Keep expression natural Do not wear hat sungl...

Page 19: ...Copyright 2021 ACTi Corporation All Rights Reserved 7F No 1 Alley 20 Lane 407 Sec 2 Ti Ding Blvd Neihu District Taipei Taiwan 114 R O C TEL 886 2 2656 2588 FAX 886 2 2656 2599 Email sales acti com...

Reviews: