background image

NMEA Data Multiplexer - NDC-4

Page 19

© 2015 Active Research Limited

Specifications

The NDC-4 ISO-Drive output is a very flexible output that is RS485, RS232, RS422 and NMEA 0183 compatible.

Parameter

Conditions

Min.

Max.

Unit

Supply

Supply voltage

External power supply

8

35

V

Supply current from external source 

(see note 1)

Supply voltage = 12v

30

40

mA

Supply voltage = 24v

15

20

mA

Supply voltage

USB powered

4.75

5.25

V

Supply current from USB (see note 1)

Supply voltage = 5v

67

75

mA

Opto-isolated Flexible Input

Input voltage b/-

Logical ‘1’/stop bit

-15.0

0.5

V

Logical ‘0’/start bit

4.0

15.0

V

Input current

Maximum is under +35v overload 

condition, Min @ 2.0v input level

1.6

9.0

mA

Differential input voltage

Required level for NMEA to be detected

1.8

2.0

V

Galvanic isolation

Between input & output

2500

V

Overdrive protection

40

V

Input Baud rate (ports 0 & 1 + USB)

Configurable Baud rate

4800

115200

bps

Input Baud rate (ports 2 & 3)

Configurable Baud rate

4800

57600

bps

Input Baud rate (port 4)

Fixed Baud rate

4800

4800

bps

ISO-Drive Flexible Output

Output  voltage  between  ISO  Out  +/A  and 

ISO Out -/B (under no load)

Logical ‘1’

-4.6

-5.0

V

Logical ‘0’

4.6

5.0

V

Output current at max load of 100 ohm

At maximum load, differential drive 

voltage reduces to 2.1v

-

21

mA

Output short circuit current (note 2)

Due to short circuit protection

50

55

mA

Galvanic isolation

From Opto input and (USB) ground

1500

V

Output Baud rate (ports 0 & 1 + USB)

Configurable Baud rate

4800

115200

bps

Data propagation delay

Under no-overload conditions

1.0

100

ms

General

Ambient temperature

-20

+70

°C

Guarantee 

Extended 

Actisense

 guarantee 

Year

Gland clamping range

Cable diameters accommodated

4.5

10

mm

IP Rating

IP66

Table 2

 – NDC-4 Specifications

All specifications are taken with reference to an ambient temperature (TA) of +25°C.

Notes:

1.

 Current consumption measured under no-load conditions.

2.

 Short circuit may be applied indefinitely. The ISO-Drive output may be short-circuited directly to a 30 volt battery 

supply without damage. A maximum current of 50mA will flow due to “polyfuse” auto-resetting fuse technology being 

used in each output.

Summary of Contents for NDC-4

Page 1: ...ard Serial data networking of marine electronic devices instruments RS232 USB 1 1 2 0 PC interfaces to the NMEA 0183 standard Actisense ISO Drive technology for a fully isolated serial data system Int...

Page 2: ......

Page 3: ...ng to the Battery Supply 9 Connecting to a Personal Computer 9 USB Driver Installation 10 Installation Guide 10 Windows 7 and Windows Vista 10 Windows XP and Windows NT 2000 11 USB Configuration 12 Lo...

Page 4: ...e NMEA sentence is validated Therefore the electronic device s supplying the NDC 4 with NMEA data retain s the sole responsibility for the NMEA data s validity Foreword Actisense recognises that instr...

Page 5: ...mode of the NDC 4 if any faults have been detected or the peak load currently on any one of the NMEA inputs High speed 32 bit ARM processor capable of up to 40 million instructions per second The NME...

Page 6: ...not always a straightforward matter The earlier versions of NMEA 0183 before v2 0 as detailed above used slightly different connection methods and signal levels the instruments had just one NMEA data...

Page 7: ...is powered and plugged into the NDC 4 this port switches to output only i e the RS232 input OPTO IN 0 no longer operates 4 A USB Input Output USB Variants Only The USB connector is designed for direct...

Page 8: ...ve Outputs The ISO Drive outputs are capable of driving up to 10 NMEA 0183 fully compliant listening devices or a mixture of NMEA 0183 devices and a Personal Computer PC communication port However if...

Page 9: ...ng on its internal battery with NO charging supply can the NDC 4 USB cable be used at the same time as powering the NDC 4 from the ships battery on the BATT terminals Connecting to a Personal Computer...

Page 10: ...on the CD and the Actisense website www actisense com Drivers for MAC OS X are provided as is and Actisense is unable to offer support for MAC related issues To download the drivers visit the Actisens...

Page 11: ...allocated to your Actisense device as well as how to change to a different COM port Windows XP and Windows NT 2000 The following instructions are for Windows XP Although not the same Windows NT 2000 u...

Page 12: ...as well as how to change to a different COM port USB Configuration To communicate with the NDC 4 the COM port number that Windows has allocated to the USB port needs to be determined The following gu...

Page 13: ...y of the settings here the software package that opens the port will specify the required values 4 Click on the Advanced button and choose a different COM Port number if required to make it compatible...

Page 14: ...s Note For a complete fresh install delete the install directory This will remove all previous settings To keep these settings do not delete the directory 3 If the program is contained within a zip fi...

Page 15: ...all Confirmation will be displayed Answer Yes and the uninstall operation will be performed automatically After successfully uninstalling the Actisense PC software the uninstall completion box will ap...

Page 16: ...The use of AIS at Baud rates lower than 38400 cannot be recommended as this could cause random AIS target data to be lost in areas of high target density To enable these settings on the NDC 4 click on...

Page 17: ...ained within the received NMEA sentence indicate that this data is not valid and should only be used with caution With the addition of two fully Baud rate configurable outputs protected by ISO Drive t...

Page 18: ...e main program Amber No flashing Initialise and self test mode No error No response required A normal operation mode that follows after the Start up mode and should last for approximately 1 second Gre...

Page 19: ...00 57600 bps Input Baud rate port 4 Fixed Baud rate 4800 4800 bps ISO Drive Flexible Output Output voltage between ISO Out A and ISO Out B under no load Logical 1 4 6 5 0 V Logical 0 4 6 5 0 V Output...

Page 20: ...USB NDC 4 USB unit pre configured for AIS NDC 4 ASW NDC 4 base unit pre configured as an Autoswitch Returns Procedure Actisense prides itself on having a very low product return rate In the unlikely...

Reviews: