background image

1) Keeping IR8200L power on. 

2) Run COM_12.exe 

3) Turn on the Device B and then active IR service program. 

4) You can see “……**********” on the DOS screen. 

5) Stop listening program, the program will generate a BIN file (LOG_RAW.BIN). 

6) Rename LOG_RAW.BIN to REC2.BIN 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

c) The third IR traffic record: 

1) Keeping IR8200L power on. 

2) Run COM_12.exe 

3) Remove Device B and then place Device A (HP Jornada). 

4) Active IR service program under Device A. 

5) You can see “……**********” on the DOS screen. 

6) Stop listening program, the program will generate a BIN file (LOG_RAW.BIN). 

7) Rename LOG_RAW.BIN to REC3.BIN 

 

===================== END =================== 

Another device 

can link with 

IR8200L 

(Device B) 

IR8200L 

 

ACT 

IR910D1 

 

 

ACT 

IR910D2 

 

To PC Com port 

Run COM_1.exe 

or COM_2.exe 

<   IR link      > 

Summary of Contents for IR8200L

Page 1: ...SW records IrDA protocol conversation from 9 6K to 115 2 Kbps It works together with ACTiSYS IrDA PC RS232 Dual head adapter IR910D You will need a real DOS system with at least one free COM port It does not decode OBEX or any other layers above IrLMP But all the information are preserved for you to read Please see the sample output LOG_LMP TXT attached This sample is an OBEX session Timing inform...

Page 2: ...DA signal itself as received by IR910D The next two bytes is the 16 bit integer representing the time interval between this IrDA byte and the previous one The unit of time is 43 58 usec II Translate To Text Files Run XLATE EXE to translate LOG_RAW BIN into LOG_PHY TXT LOG_PHY TXT and LOG_LMP TXT files III Viewing The Text Files You may use any editor or word processor to view the ASCII text files ...

Page 3: ... usec 351 means 350 usec 402 means 4000 usec 123 means 12000 usec etc d Last but not least the frame_ is an arbitrary sequential number assigned to each frame All three text files share the same sequence so that you can use it to cross reference them IV Example Using Device Embedded with IrDA Protocol IC ACT IR8200L a The first IR traffic record 1 Run COM_12 exe COM_1 exe or COM_2 exe 2 Turn on th...

Page 4: ... c The third IR traffic record 1 Keeping IR8200L power on 2 Run COM_12 exe 3 Remove Device B and then place Device A HP Jornada 4 Active IR service program under Device A 5 You can see on the DOS screen 6 Stop listening program the program will generate a BIN file LOG_RAW BIN 7 Rename LOG_RAW BIN to REC3 BIN END Another device can link with IR8200L Device B IR8200L ACT IR910D1 ACT IR910D2 To PC Co...

Reviews: