4.  Test before powering up

Before powering up an installation, it is good practice to ensure that the column 

cable is properly connected to the column. Therefore, the electrical resistance 

of each channel of the column must be controlled at the end of the cable 

connected  to  the  amplifier  side.  The  measured  electrical  resistances  values 

must correspond to the values below.

Channel

1

2

3

4

5

6

SA100P

6,6Ω

6,6Ω

6,6Ω

-

-

-

SA180P

6,6Ω

6,6Ω

6,6Ω

-

-

-

SA250P

6,6Ω

6,6Ω

6,6Ω

4,4Ω

4,4Ω

4,4Ω

SA400P

6,6Ω

6,6Ω

6,6Ω

6,6Ω

6,6Ω

6,6Ω

SA180S

6,6Ω

6,6Ω

6,6Ω

-

-

-

SA250S

3,3Ω

6,6Ω

6,6Ω

4,4Ω

4,4Ω

3,3Ω

Warning : When measuring the electrical resistance, the cable re-

sistance must be taken into account (about 1,3Ω for 100 meters of  

1,5mm² ; 0,7Ω for 100 meters of 2,5mm²)

5.  NUT control software

The NUT control software is used to tune the filtering and directivity parameters 

of StepArray columns, it is available as free download on Active Audio’s web 

site:

http://www.activeaudio.fr/en/public-address-sound-reinforcement/digital-si-

gnal-processor-nut

6.  Troubleshooting

Symptom 

Possible cause

Solution

The power LED of the 

NUT processor is not ON

A fuse burned

Replace inside the NUT 

processor (1A delayed 

fuse)

The sound is not ho-

mogeneous or distorted

Amplifier  to  column 

connection is incorrect

Make sure columns are 

properly connected, as 

described in section 3.3

Input signal level is too 

high

Reduce input signal level 

(Max signal input is ±8V 

rms as described in 7.1 

on the following page).

Filtering parameters are 

wrong

Reduce  the  gain  (Mixer 

Block). Correct the 

equalization.

There is a wiring pro-

blem.

Make sure the wiring is 

correct (see 3.3 on the 

preceding page).

The parameters of the 

StepArray block are 

wrong

Check that the parame-

ters in the StepArray 

block of NUT control are 

correct.

The column model of 

the StepArray block in 

NUT control doesn’t 

match the real column 

model.

Correct the column mo-

del in the StepArray 

block.

Summary of Contents for StepArray

Page 1: ...L a c o u s t i q u e a c t i v e Technical manual StepArray Digitally steerable column loudspeakers...

Page 2: ...3 Wiring amplifiers to columns 7 4 Test before powering up 8 5 NUT control software 8 6 Troubleshooting 9 7 Hardware specifications 10 7 1 NUT processor 10 7 2 MPA8200 amplifier 11 7 3 Columns charac...

Page 3: ...lumn speakers from 1m to 4m high SA100P 1m high flat area 21m 3 channels 8 min SA180P 1 80m high flat area 40m 3 channels 8 min SA180S 1 80m high 10 area 29m 3 channels 8 min SA250P 2 50m high flat ar...

Page 4: ...escribed in figure 3 Figure 3 MPA8200 amplifier set up 3 3 Wiring amplifiers to columns Wiring amplifiers to columns is straightforward simply connect each channel of the MPA8200 amplifier to the corr...

Page 5: ...iltering and directivity parameters of StepArray columns it is available as free download on Active Audio s web site http www activeaudio fr en public address sound reinforcement digital si gnal proce...

Page 6: ...imensions 480 x 44 x 251mm Rack 19 1U Color Black Weight 3 5 kg 7 2 MPA8200 amplifier Audio data Operating modes 8 channels independent 4 channels independent bridged Power 8 x 200W under 8 8 x 300W u...

Page 7: ...nical characteristics of StepArray columns Figure 6 StepArray column dimensions Model Dimensions L x W x D mm Weight net ship ping Cable SA100P 1024 x 124 x 131 9kg 12kg 4G SA180P 1840 x 124 x 135 17k...

Page 8: ...on position 200Hz 90 60 30 0 330 300 270 20dB 10dB 500Hz 1kHz 2kHz 4kHz 8kHz Figure 10 Horizontal directivity column SA250P 8 2 SA100P acoustical data1 20m 10m 0m 10m h 2 55m 10dB 5dB 0dB 5dB 10dB 15d...

Page 9: ...00Hz 1000Hz 2000Hz 4000Hz 8000Hz Figure 19 Sound level by octave in the axis of the listening plane in front of the column with respect to the distance from the column 8 3 SA180P acoustical data1 20m...

Page 10: ...00Hz Figure 24 Sound level by octave in the axis of the listening plane in front of the column with respect to the distance from the column 8 5 SA400P acoustical data1 20m 10m 0m 40m 30m 10m 50m 60m 7...

Page 11: ...EN60065 Established on the 6th of January 2016 by R gis CAZIN CEO 8 7 SA250S acoustical data1 0m 10m 20m 10m SA250S h 3 85m 10dB 5dB 0dB 5dB 10dB 15dB 20dB SA250S vertical directivity sound level for...

Page 12: ...www activeaudio fr info activeaudio fr Active Audio 8 Rue Johannes Gutenberg 44340 Bouguenais France Phone 33 0 2 404 666 64 Contact...

Reviews: