background image

14

LIMITED 3 YEAR WARRANTY 

Customer should not repackage and ship the ActivePure

®

 

Induct Guardian I unit due to possibility of irreparable 

damage. For warranty service, please contact ActivePure 

Customer Service at 800.572.1446.

WHAT IS COVERED BY THIS WARRANTY? 

We warrant the ActivePure

®

 Induct Guardian I to the 

Customer, subject to the conditions below, against 

defects in workmanship or material, provided that the 

products are returned to ActivePure Manufacturing, LLC 

within the following time periods: 
•   ActivePure

®

 Induct Guardian I (excluding the ActivePure 

Cell and Lamp) within three (3) years of date of 

purchase.

•   ActivePure

®

 Cell and Lamp within one (1) year of date 

of purchase if the Induct Guardian I is connected to a 

power source where the ActivePure Cell is “ON” 100% 

of the time.

•  If the Induct Guardian I is connected to the fan circuit 

where the ActivePure

®

 Cell cycles “ON and OFF” with 

the system fan, the ActivePure Cell is only covered by a 

ninety (90) day warranty from date of purchase.

INSTALLATION AND MAINTENANCE REQUIREMENTS

This warranty is expressly conditioned upon proper 

installation, operation, cleaning and maintenance, all in 

accordance with the Owner’s Manual. Failure to meet any 

of these requirements will void this warranty. Servicing of 

your ActivePure

®

 Induct Guardian I using parts other than 

genuine ActivePure parts will also void this warranty. 

HOW TO OBTAIN WARRANTY SERVICE

 

Customer must go online to www.ActivePure.com/

Warranty or call 1.800.572.1446 to register their unit 

and activate their warranty within 1-year from date 

of purchase. ActivePure

®

 Induct Guardian I will repair 

or replace and return the product, without charge 

and within a reasonable period of time, subject to the 

conditions herein, if its examination shall disclose any 

part to be defective in workmanship or material. If we, 

in our discretion, are unable to repair the product after 

a reasonable number of attempts, we will provide either 

a refund of the purchase price or a replacement unit, at 

the company’s option. We reserve the right to inspect 

and/or require confirmation of installation method. We 

reserve the right to inspect and/or require confirmation 

of installation method. 

WHAT IS NOT COVERED BY THIS WARRANTY

Ordinary wear and tear shall not be considered a defect 

in workmanship or material. These warranties do not 

apply for loss or damage caused by accident, fire, abuse, 

misuse, improper installation, leaking, modification, or 

misapplication. This warranty is non-transferable.

MISSING SERIAL NUMBERS AND UNAUTHORIZED 

CHANNELS

If a valid serial number is missing from the product, the 

warranty will be voided. ActivePure

®

 Induct Guardian 

I products are for sale through authorized sales 

representatives only. Warranties are voided if a product is 

purchased through unauthorized channels; this includes 

company sponsored or independent websites that 

are not authorized to use ActivePure

®

 Induct Guardian 

I trademarked names, images and logos as well as 

Internet auction sites (e.g. eBay and craigslist). To confirm 

warranty coverage prior to purchasing a product, contact 

ActivePure

® 

Customer Service at 800.572.1446 with the 

serial number located on the back of the unit.

EXCLUSION OF OTHER WARRANTIES AND CONDITIONS

 

EXCEPT AS PROVIDED HEREIN, WE MAKE NO 

REPRESENTATION OR WARRANTY OF ANY KIND. ALL 

OTHER WARRANTIES OF ANY KIND, EXPRESS OR IMPLIED, 

ARE HEREBY EXPRESSLY DISCLAIMED, INCLUDING ANY 

IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS 

FOR A PARTICULAR PURPOSE. 

LIMITATION OF LIABILITY FOR SPECIAL, INCIDENTAL, 

OR CONSEQUENTIAL DAMAGES 

WE SHALL NOT IN ANY CASE BE LIABLE FOR SPECIAL, 

INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING 

FROM BREACH OF EXPRESSED OR IMPLIED WARRANTIES, 

CONDITIONS, GUARANTEES OR REPRESENTATIONS, 

BREACH OF CONTRACT, NEGLIGENCE OR ANY OTHER 

LEGAL THEORY. 

Such excluded damages include, but 

are not limited to, loss of profits or revenue, and loss of 

the use of the products, and any loss caused by leaks or 

other water damage. 

FOR U.S. APPLICATION ONLY 

This warranty gives you specific legal rights, and you may 

also have other rights which vary from state to state. 

Some states do not allow limitations on warranties, or on 

remedies for breach. In such states, the above limitations 

may not apply to you. 

FOR CANADIAN APPLICATION ONLY 

Exclusion of Subsequent Owners: Except as otherwise 

required by applicable legislation, this warranty is not 

transferable. This warranty gives you specific legal rights 

and you may also have other rights which vary from 

province to province. Some provinces and territories 

do not allow limitations on warranties, or on remedies 

for breach. In such provinces or territories, the above 

limitations may not apply to you. If any provision of this 

warranty or part thereof is held by a court of competent 

jurisdiction to be invalid, illegal, or unenforceable, the 

validity, legality and enforceability of the remaining 

provisions or parts thereof will not in any way be 

affected or impaired within the jurisdiction of that 

court. This entire warranty shall continue to be valid, 

legal and enforceable in any jurisdiction where a similar 

determination has not been made. 

This warranty is provided by:

ActivePure Manufacturing, LLC

1300 Valley Drive 

Bristol, VA  24201

SERVICE

Every effort is made to ensure customers receive an 

up-to-date instructions manual on the use of our 

products; however, from time to time, modifications to 

our products may without notice make the information 

contained herein subject to alteration. For the latest 

information, please visit our website at www.activepure.

com or www.activepure.com/manuals. 

LIMITED THREE (3) YEAR WARRANTY

Summary of Contents for B1013U

Page 1: ...READ MANUAL CAREFULLY FOR PROPER USE AND OPTIMAL OPERATION ...

Page 2: ...placement Parts 3 Recommended Installation Tools 4 Installation Requirements 4 Metal Ductwork Installation 5 Fiberglass Ductwork Installation 6 7 Maintenance UV Lamp Indicator 8 Changing the ActivePure Cell 8 Replacing the Ballast 9 10 Troubleshooting Guide 11 13 Warranty Information 14 FCC Declaration of Conformity 15 Responsible Party 15 PRODUCT OVERVIEW Congratulations on your purchase of the A...

Page 3: ...ctrician failure to do so will void warranty of the product This unit must never be used with an extension cord Do not connect this unit to any voltage source above 32 volts doing so will cause damage to the unit Power Cord Mounting Plate UV bulb indicator Replaceable ActivePure Cell includes UV Bulb Safety Switch IMPORTANT SAFETY INSTRUCTIONS PRODUCT CONTENTS INSTALLATION HARDWARE SUPPLIED REPLAC...

Page 4: ... 4 Nut Driver Bit Min 9 x 9 Metal Ductwork Min 10 x 10 Fiberglass Ductwork Air Handle Max 15 ft RECOMMENDED INSTALLATION TOOLS INSTALLATION REQUIREMENTS When the unit is installed in a roof mounted HVAC system the unit must be protected from elements This unit must be installed by a licensed HVAC contractor or electrician Failure to do so will void warranty of the product Power Connection Requirem...

Page 5: ...tal duct if needed 1 4 a Using the mounting plate mark 4 Cutting Method holes on duct b Drill 4 holes where marked c Cut between holes using tin snips ALTERNATE CUTTING METHOD METAL DUCTWORK INSTALLATION 5 Remove backing from mounting plate adhesive gasket Power Connection Requirements This device is designed to operate using a 24 VAC 40Va transformer Transformers supplied with a straight cooling ...

Page 6: ...g 3 5 hole saw 4 Drill 4 holes at corner screw locations using a 3 8 drill bit FIBERGLASS DUCTWORK INSTALLATION Power Connection Requirements This device is designed to operate using a 24 VAC 40Va transformer Transformers supplied with a straight cooling or HVAC system may be used to power the device but must be verified it s capable of handling the additional device load before installation If th...

Page 7: ...r large opening in the mounting plate over 3 5 opening in duct and press plate to duct The adhesive gasket will hold the mounting plate into place Tighten toggle bolts DO NOT OVERTIGHTEN 9 Insert unit into opening Be sure the air will pass through the ActivePure Cell honeycomb matrix 10 Secure the unit to the mounting plate with four 4 thumb nuts FIBERGLASS DUCTWORK INSTALLATION CONTINUED NOTE Uni...

Page 8: ... into the base unit Be sure Air Flow Honeycomb Cell direction is correct 7 Secure with 2 thumb screws 8 Insert the unit into the mounting plate 9 Secure unit with 4 thumb nuts 10 Reconnect power cord MAINTENANCE UV LAMP INDICATOR CHANGING THE ACTIVEPURE CELL 1 Disconnect unplug power cord from unit NOTE Always follow OHSA electrical lockout safety requirements to prevent accidental release of ener...

Page 9: ...ire straight out 1 Disconnect unplug power cord from unit REPLACING THE BALLAST Power Cord NOTE Always follow OHSA electrical lockout safety requirements to prevent accidental release of energy during service or maintenance activities UV Light in operation disconnect unit from power cord before servicing failure to follow warnings may result in severe eye damage Disconnect power at the breaker or ...

Page 10: ... power cord turn breaker or fuse power back on and check for proper operation NOTE LED indicator should be lit when in operation LED INDICATOR 6 To reconnect wiring insert wire into wire pocket in ballast until bottomed Gently pull wire to ensure it is properly locked into place REPLACING THE BALLAST CONTINUED ...

Page 11: ...power is not supplied to the unit Check power source and verify Induct Safety Switch is fully depressed Safety switch plunger is located underneath the unit and is depressed when unit is secured to mounting plate 3 Re plug the black and white wires to the ballast 4 Remove unit from the duct by taking off the 4 11 32 thumb nuts that secure the unit to the mounting plate 5 Remove the 2 Phillips head...

Page 12: ...or tabs and pulling wire straight out 6 To reconnect wiring insert wire into wire pocket in ballast until bottomed Gently pull wire to ensure it is properly locked into place 1 Disconnect unplug power cord from unit NOTE Always follow OHSA electrical lockout safety requirements to prevent accidental release of energy during service or maintenance activities TROUBLESHOOTING GUIDE CONTINUED 2 If con...

Page 13: ... cover and secure the original four 4 screws Replacement Part Numbers Ozone Free ActivePure Cell Includes UV Bulb Item 9950231 Ballast Item 9950102 Power Cord Item 9950103 Base Unit ActivePure Cell To order replacement parts contact your sales representative or ActivePure Customer Service for further assistance at 800 572 1446 or email customerservice ActivePure com TROUBLESHOOTING GUIDE CONTINUED...

Page 14: ...epresentatives only Warranties are voided if a product is purchased through unauthorized channels this includes company sponsored or independent websites that are not authorized to use ActivePure Induct Guardian I trademarked names images and logos as well as Internet auction sites e g eBay and craigslist To confirm warranty coverage prior to purchasing a product contact ActivePure Customer Servic...

Page 15: ... be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the Independent Owner for help FCC ...

Page 16: ...n regarding the use of this product please call Customer Service 1 800 572 1446 or email at customerservice ActivePure com www activepure com ActivePure Manufacturing LLC Bristol VA 24201 800 572 1446 ActivePure Manufacturing All Rights Reserved ...

Reviews: