Condenser Section

Single DC inverter fan motor, with the following features:

 

Low noise operation.

 

Inverter rotary compressor.

Electrical Section

The electrical section is composed of a separate panel for controls, protecting the components from the elements. 

The electrical section is composed of a separate panel for controls, protecting the components from the elements. 

Durable Design and Construction

ActronAir is an Australian manufacturer with proven high quality air conditioning products. Known for their durability and 

ActronAir is an Australian manufacturer with proven high quality air conditioning products. Known for their durability and 
reliable performance, these products are designed and built to withstand the extreme weather conditions.

reliable performance, these products are designed and built to withstand the extreme weather conditions.

The galvanized steel cabinet, with powder coated epoxy enamel finish, resists the toughest conditions. 

The galvanized steel cabinet, with powder coated epoxy enamel finish, resists the toughest conditions. 

Gold Hydrophillic Coat Coil Protection heat exchangers ensures an enhanced heat transfer with increased performance 
efficiency.

System Flexibility

The ActronAir air conditioning units are the first choice for residential, office, schools and other air conditioning facilities 
applications, both for new construction or retrofitting projects.

Refrigerant Handling and Accountability

ActronAir strongly urges that all service technicians make every effort to eliminate the emission of refrigerants to the 
atmosphere. Everyone must act in a responsible manner to conserve refrigerants.

Sustainability and Environmentally Friendly

The air conditioning system is supplied with a zero ozone depleting low GWP R-32 refrigerant, which has no phase out or 
replacement concern.

With cooling and heating performance capacity that are among the best in the market, the ActronAir air conditioning 
units provide the solution for the reduction of energy consumption, CO2 emission, high fuel dependency and high 

network grid demand.

04.  Safety Instructions

 

Only licensed HVAC technicians* should install and service this air conditioning equipment. Improper service or 
alteration by an  unqualified technician could result in significant and major damage to the product or property which 
may render your warranty null and void. Such unqualified service could also lead to severe physical injury or death. 
Follow all safety instructions in this literature and all warning labels that are attached to the equipment.

 

Prevailing WH&S regulations must be observed and will take precedence to the safety instructions contained on 
this manual. Safe work practices and environment must be the paramount importance in the performance of all the 
service procedures.

 

Ensure that unit installation complies with relevant council regulations and building code standards.

 

All electrical wiring must be in accordance with current electrical authority regulations and all wiring connections to 
be as per electrical diagram provided.

 

Secure the fans against accidental contact. Beware of pinch point and sharp edges which can cause cutting injury.

 

Always wear appropriate PPE, remove any dangling jewellery and protect long hair by wearing a cap.

 

Make sure that safety guards and panel covers are always firmly secured and not damaged.

 

This appliance is not intended for use by young children or infirm persons unless they have been adequately 
supervised by a responsible person to ensure that they can use the appliance safely. Young children should be 
supervised to ensure that they do not play with the appliance.

 

Installer must incorporate a means of electrical disconnection (isolator) in the sub mains fixed wiring in accordance 
with the latest version of the AS/NZS 3000 (also known as Australian Wiring Rules).

 

Secure the power cords and control cables that goes in/out the unit. 

*

Qualifications required will be appropriate Electrical, Refrigeration and Refrigerant Handling License and Training 

dependent on local State/Territory regulations.

Summary of Contents for BRE-026CS

Page 1: ...e installing or operating your air conditioning unit Make sure to save this manual for future reference Model Numbers BRE 026CS BRE 035CS BRE 050CS BRE 070CS CAUTION The system is charged with flammab...

Page 2: ...0 14 Test Run 21 MUST BE INSTALLED BY A LICENSED ELECTRICIAN DIY DIY DIY ALL ELECTRICAL WORK MUST BE PERFORMED BY A LICENSED ELECTRICIAN FOR COMPLIANCE WITH QUEENSLAND ELECTRICAL SAFETY REGULATIONS 20...

Page 3: ...All electrical wiring must be in accordance with current electrical authority regulations and all wiring connections to be as per electrical diagram provided with the unit 03 General Information The A...

Page 4: ...mance capacity that are among the best in the market the ActronAir air conditioning units provide the solution for the reduction of energy consumption CO2 emission high fuel dependency and high networ...

Page 5: ...e room size corresponds to the room area as specific for operation without continuously operating open flames for example an operating gas appliance and ignition sources for example an operating elect...

Page 6: ...quipment does not leak or contain moisture Take into consideration the correct amount of refrigerant charge specified for the system to ensure efficient unit operations When charging is complete recla...

Page 7: ...ded with the air conditioner must be purchased separately Name Quantity Illustration Tubing Fittings Soundproof Insulation Sheath 2 Seal Sponge 1 Wired Controller Wired Controller 1 Wired Controller S...

Page 8: ...te controller based on customer preferences and requirements and install in an appropriate place Refer to catalogues and technical literature for guidance on selecting a suitable remote controller 07...

Page 9: ...locations In areas with oil drilling or fracking In areas with caustic gases in the air such as near hot spring In enclosed spaces such as cabinets In areas with strong electromagnetic waves In areas...

Page 10: ...nt te ed d h ho oo ok k Air filter Electric control box Air filter Air Intake Condensate Drain 25mm OD Air Intake Air Intake Model Outline Dimensions Supply Air Return Air Mounting Width Height Total...

Page 11: ...ng screw bolt Pipe hanging and embedding screw bolt Original Concrete Bricks Use an embedding screw bolt crock and stick harness Roof beam Hanging screw bolts Blade shape insertion Slide insertion Han...

Page 12: ...uld be apart far enough to avoid air passage short cycling Canvas tie in Canvas tie in Air outlet Isolation booth Isolation booth checking orifice Air inlet Air dust filter Air return flange Ventilati...

Page 13: ...ide using the following steps 1 Take off ventilation panel and flange cut off the staples at the side rail 2 Stick the attached seal sponge as per the indicating place see below and then change the mo...

Page 14: ...nsure correct electrical tag out procedures are followed before commencing work Take rear ventilated as example Motor Maintainance 1 Remove the ventilated panel 2 Remove the blower housing 3 Remove th...

Page 15: ...o the unit s outlet pipe Sheath the mouth of the hose and clip it firmly with a pipe clasp 3 Ensure the drain pipe has flex by installing clear tube or similar to prevent drain breakage or cracking Dr...

Page 16: ...TE When connecting multiple drainpipes install the pipes as shown below 0 550mm 100mm 4 Using a 65 mm core drill drill a hole in the wall Make sure that the hole is drilled at a slight downward angle...

Page 17: ...lfunction If you discharge the water directly into a sewer make sure that the drain has a U or S pipe to catch odour that might otherwise come back into the house Drainage Test Check whether the drain...

Page 18: ...ed size to ensure minimal voltage drop at supply terminals No other equipment should be connected to the same sub circuit as the A C unit The unit s power information can be found on the rating sticke...

Page 19: ...N L POWER SUPPLY See Outdoor Unit MRC Installation Guide for suggested minimum N INDOOR UNIT N L2 Field wiring by Installer 1mm 2 CORE EARTH S S 14 0 20 0 44mm SHIELDED DATA CABLE WITH SHIELD WIRE CON...

Page 20: ...ALARM NO RELAY OUTPUT 24V AC DC 0 5A MAX BY INSTALLER WIRED CONTROLLER WC 02 4 CORE SHIELDED CABLE COMES WITH WC 02 CN34 CN10 CHOKE M INDOOR COIL TEMPERATURE SENSOR T2 BLACK ROOM TEMPERATURE SENSOR T1...

Page 21: ...mperature is being registered correctly c Ensure the indicators on the wall control and the display panel on the indoor unit work properly d Check the airflow supplied matches the design conditions sp...

Page 22: ...Installation and Commissioning Guide Bulkhead 2 Split System Doc No 9590 5011 Ver 1 211217 22 Notes Bulkhead Split System...