SAFETY AND OPERATIONAL PRECAUTIONS
1. Read all instructions in this manual before operating the air conditioning unit. Failure to
do so may result in damage to the unit and void your warranty.
2. Turn-Off power from mains supply by removing fuse or switching the circuit breaker to
the "Off" position before installation or servicing this control interface.
3. Follow sound Lock Out & Tag Out procedures to ensure that power supply is not
re-energised accidentally.
4. This control interface has power supply from the control board via telephone connector,
with voltage of 18/30VDC protected by 250mAT external fuse & maximum power input of
0.8W. Ensure that this unit is not installed on voltages higher than 30V DC supply.
5.
Installation and/or servicing must be carried out by a qualified installer or technician.
6. Ensure that the unit installation complies with relevant council regulations and building
code standards. All electrical wiring must be in accordance with current electrical
authority regulations and all wiring connections to be as per electrical diagram provided.
7. WH&S rules and regulations must be observed and will take precedence during
installation process.
8. Only use this wall controller with an ActronAir air conditioner as described in this
operating manual.
ACCESS PANELS AND GUARDS:
NEVER remove any access panels or guards as this
could cause injury from electric shock and burns from extremely hot components. Never
allow any bodily parts such as fingers or objects to protrude through the fan guards or any
other opening as they could cause personal injury and damage the air conditioner.
RETURN AIR FILTER:
The air conditioner must never be operated without a return air filter
as this will allow a build up of dust or dirt on the indoor coil. This is very difficult to clean and
can cause the system to operate inefficiently or even fail.
CRANKCASE HEATER PRECAUTION:
The main power (switch board) to the system
must be kept ON at all times to prevent damage to the outdoor compressor. Should the
main power be disconnected or interrupted for 6 hours or longer, then no attempt should
be made to start the system for 2 hours after the power has been restored to outdoor unit.
This allows the compressor to warm up, and remove any liquid refrigerant that may cause
damage.
OPERATIONAL PRECAUTIONS
SAFETY PRECAUTIONS