42
Installation and Commissioning Guide
Hercules Package Unit
Installation and Commissioning Guide - Hercules Package Unit
Doc. No.0525-021
Ver. 21 221110
18. Menu Tree
18.01. Main / Status Menu
NOTES
:
To toggle (scroll)
Up
or
Down
from existing menu,
press
or
button.
Main Menu
* Condenser Fan1 = Fan1 and Fan 2
** Condenser Fan2 = Fan3 and Fan 4
E- A
F
2
Status Heat Reclaim
E11
Supply-Room
ReClaim D_Out / Mech Heat en.
Supply Fan 1 Status
E12
Actual / Max Speed
DC Voltage / DC Current
Output Power
Elec. Temperature
Supply Fan 2 Status
E13
Actual / Max Speed
DC Voltage / DC Current
Output Power
Elec. Temperature
Compressor 1: On / Off
E9
Comp Request 1: %
Rev. Valve 1: On / Off
Crank Heater 1: On / Off
ReHeat Valves SV1 & SV3 / SV2 : On / Off
Compressor 2: On / Off
E10
Comp Request 2: %
Rev. Valve 2: On / Off
Crank Heater 2: On / Off
ReHeat Valves SV4 & SV6 / SV5 : On / Off
Outdoor Fan 1 Status
E16
Actual / Max Speed
DC Voltage / DC Current
Output Power
Elec. Temperature
Supply Fan 3 Status
E14
Actual / Max Speed
DC Voltage / DC Current
Output Power
Elec. Temperature
Supply Fan 4 Status
E15
Actual / Max Speed
DC Voltage / DC Current
Output Power
Elec. Temperature
E- B
F-B
Outdoor Fan 3 Status
E18
Actual / Max Speed
DC Voltage / DC Current
Output Power
Elec. Temperature
Outdoor Fan 4 Status
E19
Actual / Max Speed
DC Voltage / DC Current
Output Power
Elec. Temperature
Outdoor Fan 2 Status
E17
Actual / Max Speed
DC Voltage / DC Current
Output Power
Elec. Temperature
LEGEND
:
1
Available when enabled via Clock / Scheduler
D1
.
2
Available when enabled via Service Menu.
E- A
F
A. On /Off Unit
B. Setpoint
C. Mode of Operation
D. Clock / Scheduler
E. Status
Unit “On” / “OFF”
A1
Room Setpoint °C
B1
Room Setpoint %rH
Cool Only
C1
1
After Hours operation duration
D7
1
Special Day 1-12
D8-D19
1
Night Mode
D20-D23
Day / Date / Hour
D1
Enable Scheduler / Night Mode
Ext. Fan Spd / Supply Temp
E1
Outside Temp / Ext. Demand
Cond Temp 1 / Cond Temp 2
E2
Low Press 1 / High Press 1
Low Press 2 / High Press 2
Fan Only
C1
Day Light Saving Time
D2
Display Backlight
A2
Heat Only
C1
Auto Changeover
C1
1
Scheduler
D3-D6
Supply Pressure
E3
Supply Volume
Filter Pressure
Suction / Disch Temp 1
Suction / Disch Temp 2
2
RS485 Outside Probe
E4
Temperature / Humidity
Dew Point / Enthalpy
* Condenser Fan 1: %
E8
** Condenser Fan 2: %
Supply Fan %
Economy Cycle %
DRM 1 --> 3
E7
Remote (On/Off) / Mode / De-hum
HP 1 / LP 1 Switch Ok / Fault
E6
LP 1 Switch Bypass
HP 2 / LP 2 Switch Ok / Fault
LP 2 Switch Bypass
2
RS485 Room Probe
E5
Temperature / Humidity
Dew Point / Enthalpy