Air Filter Cleaning Procedure

A clogged air conditioner can reduce the cooling efficiency of your unit, and can also be bad for your health. Make sure to 
clean the filter once every two weeks. (Refer to image on next page)

1.  The air filter is at the top of the indoor unit. 
2.  Grip the tab on the end of the filter, lift it up,then  pull it towards yourself.(See image below)
3.  Clean the air filter with warm, soapy water. Be sure to use a mild detergent.
4.  Rinse the filter with fresh water, then shake off excess water.
5.  Dry it in a cool, dry place, and refrain from exposing it to direct sunlight.
6.  Slide the air filter back into place and clip it into the indoor unit.

PULL

HOLD BOTH SIDES OF THE FILTER 

(AS SHOWN IN THE IMAGE) AND 

PULL UPWARDS.

Filter is held in place by mag pull magnets, which helps in easily re-fitting the filter after cleaning.

WASH FILTER THOROUGHLY.

ƒ

 Page 12 

„

Cleaning Your Indoor Unit

 BEFORE CLEANING OR

 

 MAINTENANCE

ALWAYS TURN OFF YOUR AIR CONDITIONER
SYSTEM AND DISCONNECT ITS POWER SUPPLY
BEFORE CLEANING OR MAINTENANCE.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 CAUTION

Only use a soft, dry cloth to wipe the unit clean. 
If the unit is especially dirty, you can use a cloth 
soaked in warm water to wipe it clean.

• 

Do not  

use chemicals or chemically treated 

cloths to clean the unit

• 

Do not 

use benzene, paint thinner, 

polishing powder or other solvents to clean 
the unit. They can cause the plastic surface 
to crack or deform.

• 

Do not

 use water hotter than 40°C (104°F) 

to clean the front panel. This can cause the 
panel to deform or become discolored.

Cleaning Your Air Filter

A clogged air conditioner can reduce the cooling 
efficiency of your unit, and can also be bad for 
your health. Make sure to clean the filter once 
every two weeks.
1.   Lift the front panel of the indoor unit. The

air filter is under the top air inlet grill. 

2.   Grip the tab on the end of the filter, lift it

up,then   pull it towards yourself.

3.   Now pull the filter  out.

 

4.   Clean the large air filter with warm, soapy 

water. Be sure to use a mild detergent.

Care and Maintenance

3       

5.   Rinse the filter with fresh water, then shake 

off excess water.

6.   Dry it in a cool, dry place, and refrain from 

exposing it to direct sunlight.

 

7.

 

Close the front panel of the indoor unit.

 CAUTION

Do not touch air freshening (Plasma) filter for 
at least 10 minutes after turning off the unit.

Ca

re and 

Maintenance

Fig. 5.1

Filter Tab

Summary of Contents for Serene 2

Page 1: ...anual Model Numbers WRC 026CS WRE 026CS WRC 035CS WRE 035CS WRC 050CS WRE 050CS WRC 072CS WRE 072CS WRC 085CS WRE 085CS IMPORTANT NOTE Please read this manual carefully before operating your air condi...

Page 2: ...l Information 3 02 Safety Instructions 3 03 Unit Specification and Features 5 03 01 Unit Parts 5 03 02 Achieving Optimal Performance 6 03 03 Features 6 03 04 Setting Vertical Angle of Air Flow 7 03 05...

Page 3: ...ctions contained on this manual Safe work practices and environment must be the paramount importance in the performance of all the service procedures This appliance is not intended for use by young ch...

Page 4: ...airconditionerisusedtogetherwithotherheatingdevices thoroughlyventilatetheroomtoavoidoxygendeficiency DONOTclimbontoorplaceobjectsontopoftheoutdoorunit DONOToperatetheairconditionerwhenusingfumigantin...

Page 5: ...N is set IONISER SWING TURBO ECO BREEZE AWAY INTUITIVE PROXIMITY SENSOR or QUIET feature is turned on Displayed for three seconds when TIMER OFF is set IONISER SWING TURBO ECO BREEZE AWAY INTUITIVE PR...

Page 6: ...as been restored Anti mildew When the unit is turned off after COOL AUTO or DRY mode the unit will continue to operate a low power to dry up condensed water to prevent mildew growth Easyconnect Contro...

Page 7: ...em will enter freeze protection mode 03 04 Setting Vertical Angle of Air Flow While the unit is on use the SWING button on the remote control to set the vertical angle airflow direction Refer to Remot...

Page 8: ...s not available in FAN or DRY mode Page 10 The SLEEP function is used to decrease energy use while you sleep and don t need the same temperature settings to stay comfortable This function can only be...

Page 9: ...ext page 2 Press the MANUAL CONTROL button one time to activate FORCED AUTO mode The display will show 24 0c 3 Press the MANUAL CONTROL button again to activate FORCED COOLING mode The display will sh...

Page 10: ...ng Fan Blades Always make sure that all power supply to the Outdoor Fans are turn Off and isolated Observe WH S safety procedures do not wear loose clothing and any jewellery when working near the fan...

Page 11: ...sibility of water entering the electrical compartments during cleaning of the condenser coil Coil Cleaning Procedures Disconnect power to the unit Remove the louvred panels from the unit to gain acces...

Page 12: ...back into place and clip it into the indoor unit PULL HOLD BOTH SIDES OF THE FILTER AS SHOWN IN THE IMAGE AND PULL UPWARDS Filter is held in place by mag pull magnets which helps in easily re fitting...

Page 13: ...off the unit and disconnect the power Remove batteries from remote control Maintenance Pre Season Inspection After long periods of non use or before periods of frequent use do the following Check for...

Page 14: ...generated from the defrosting process The indoor unit makes noises A rushing air sound may occur when the louvre resets its position A squeaking sound may occur when running the unit due to expansion...

Page 15: ...lace batteries The Unit s 3 minute protection has been activated Wait three minutes after restarting the unit Timer is activated Turn timer off The unit starts and stops frequently There s too much or...

Page 16: ...d Trade Marks of Actron Engineering Pty Limited ActronAir is constantly seeking ways to improve the design of its products Therefore specifications are subject to change without notice Document 9590 4...

Reviews: