Page 18
SPECIAL CONSIDERATIONS FOR EXTREME
WEATHER
If the unit is exposed to heavy wind:
Install unit so that air outlet fan is at a 90° angle to the
direction of the wind. If needed, build a barrier in front of
the unit to protect it from extremely heavy winds.
See Fig. 6.1 and Fig. 6.2 below.
DO NOT INSTALL UNIT IN THE FOLLOWING
LOCATIONS
Near an obstacle that will block air inlets and outlets
Near a public street, crowded areas, or where noise from
the unit will disturb others
Near animals or plants that will be harmed by hot air
discharge
Near any source of combustible gas
In a location that is exposed to large amounts of dust
In a location exposed to excessive amounts of salty air
Strong wind
Strong wind
Strong wind
Fig. 6.1
Fig. 6.2
Wind Baffle
Step 1: Select installation location
Before installing the outdoor unit, you must choose an
appropriate location. The following are standards that will
help you choose an appropriate location for the unit.
Proper installation locations meet the following standards:
þ
Meets all spatial requirements shown in Installation
Space Requirements (Fig. 6.3)
þ
Good air circulation and ventilation
þ
Firm and solid—the location can support the unit and
will not vibrate
þ
Noise from the unit will not disturb others
þ
Protected from prolonged periods of direct sunlight
or rain
6. Outdoor Unit Installation
Serene Wall Hung Split System
Installation Instructions – Outdoor Unit
PRIOR TO INSTALLATION
Before installing the outdoor unit, refer to the label on the
product box to make sure that the model number of the
outdoor unit matches the model number of the indoor
unit.
Step 1: Select installation location
Before installing the outdoor unit, you must choose an
appropriate location. The following are standards that will
help you choose an appropriate location for the unit.
Proper installation locations meet the following
standards:
þ
Good air circulation
þ
Convenient drainage
þ
Sufficient clearances for periodic maintenance and
service access.
þ
Noise from the unit will not disturb other people
þ
Firm, level and solid—the location will not vibrate and
strong enough to support the weight of the unit
þ
Fit anti-vibration rubber (not provided with the unit)
under the unit feet to reduce noise and vibration
transfer through the foundation. Make sure that
vibration rubbers are rated to provide sound and
stable support without impairing the unit’s structural
integrity.
DO NOT install unit in the following locations:
Near any source of heat, steam, or combustible gas
Near flammable items such as curtains or clothing
Near any obstacle that might block air circulation
Near the doorway
In a location subject to direct sunlight