1. Safety Precautions

Serene Wall Hung Split System

 

CAUTION

 

   

Do not

 install the unit in a location that may be exposed to combustible gas leaks. If combustible gas accumulates 

around the unit, it may cause fire.

   

Do not 

install your air conditioner in a wet room such as a bathroom or laundry room. Too much exposure to water 

can cause electrical components to short circuit.

1.  The product must be properly earthed at the time of installation, or electrical shock may occur.
2.  Install drainage piping according to the instructions in this manual. Improper drainage may cause water damage to 

your home and property.

 

SAFETY INSTRUCTIONS

1.  Prevailing WH&S regulations must be observed and will take precedence to the safety instructions contained on 

this manual. Safe work practices and environment must be the paramount importance in the performance of all the 
service procedures.

2.  Ensure that unit installation complies with relevant council regulations and building code standards.
3.  All electrical wiring must be in accordance with current electrical authority regulations and all wiring connections to 

be as per electrical diagram provided.

4.  Always wear appropriate PPE, remove any dangling jewellery and protect long hair by wearing a cap.
5.  Make sure that safety guards and panel covers are always firmly secured and not damaged.
6.  This appliance is not intended for use by young children or infirm persons unless they have been adequately 

supervised by a responsible person to ensure that they can use the appliance safely. Young children should be 
supervised to ensure that they do not play with the appliance.

7.  Installer must incorporate a means of electrical disconnection (isolator) in the sub mains fixed wiring in accordance 

with the Australian wiring rule (AS3000).

8.  Secure the power cords and control cables that goes in/out the unit. Use the cable ties provided in the control box.

 

WARNING

1.  Carefully read all the Safety Precautions before installation.
2.  In certain functional environments, such  as kitchens, server rooms, etc., the use of specially designed                                        

air-conditioning units is highly recommended.

3.  Only qualified HVAC technicians* should install, repair and service this air conditioning unit. Improper service or 

alteration by unqualified technician could result in significant and major damage to the product or property which 
may render your warranty null and void. Such unqualified service could also lead to severe physical injury or death. 
Follow all safety instructions in this literature and all warning labels that are attached to the equipment.

4.  During installation, ensure there are no refrigerant leaks. Refrigerant is toxic and poses a serious health and safety risk.

 * 

Qualifications required will be appropriate Electrical, Refrigeration and Refrigerant 

Handling License & Training, dependent on local State/Territory regulations.

Summary of Contents for Serene WRC-026AS

Page 1: ...your new air conditioning unit and keep it near the unit for future reference INSTALLATION MANUAL Wall Hung Split System Air Conditioner Model Numbers WRC 026AS WRE 026AS WRC 035AS WRE 035AS WRC 050A...

Page 2: ...door Unit Installation 09 5 Outdoor Unit Installation 18 6 Refrigerant Piping Connection 22 7 Parts Overview 08 4 Table of Contents Installation Manual Leak Test and Air Evacuation 32 9 Electrical and...

Page 3: ...nstalled in accordance with national regulations Failure to observe a caution may result in injury or equipment damage CAUTION Note about Fluorinated Gases 1 This air conditioning unit contains fluori...

Page 4: ...damaged 6 This appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the appliance safel...

Page 5: ...ult in water leakage electrical shock fire or cause the equipment to fail Name Shape Quantity Installation template 174mm 230mm 55mm 1 Mounting plate 1 Clip anchor 5 Mounting plate fixing screw ST3 9...

Page 6: ...e 6 12cm 2 3m 12cm 15cm Select Installation Location Attach Mounting Plate Drill Wall Hole Determine Wall Hole Position 1 2 3 4 3 Installation Summary Serene Wall Hung Split System Installation Overvi...

Page 7: ...on Summary Serene Wall Hung Split System Installation Overview Mount Indoor Unit 1 L 2 N S Connect Wiring Prepare Drain Hose Connect Piping 5 6 7 Leak test and evacuate the refrigeration system 8 Perf...

Page 8: ...Page 8 4 Parts Overview Serene Wall Hung Split System Fig 4 1 Parts Overview...

Page 9: ...devices e g TV radio computer DO NOT install unit in the following locations Near any source of heat steam or combustible gas Near flammable items such as curtains or clothing Near any obstacle that...

Page 10: ...n of Mounting Plate Step 3 Drill wall hole for connective piping You must drill a hole in the wall for refrigerant piping the drainage pipe and the signal cable that will connect the indoor and outdoo...

Page 11: ...nit Outline 55 Installation Overview MOUNTING PLATE DIMENSIONS Different models have different mounting plates In order to ensure that you have ample room to mount the indoor unit the diagrams to the...

Page 12: ...it Any dents in the piping will affect the unit s performance If refrigerant piping is already embedded in the wall do the following Step 1 Hook the indoor unit on the mounting plate Keep in mind that...

Page 13: ...Based on the position of the wall hole relative to the mounting plate choose the side from which the piping will exit the unit 2 If the wall hole is behind the unit keep the knock out panel in place...

Page 14: ...ver it can also be attached to the right hand side 1 To ensure proper drainage attach the drain hose on the same side that your refrigerant piping exits the unit 2 Attach drain hose extension purchase...

Page 15: ...OUT TAG OUT PROCEDURES TO BE USED ETC Step 6 Connect signal cable The signal cable enables communication between the indoor and outdoor units You must first choose the right cable size before preparin...

Page 16: ...ic panel on the back NOTE ABOUT WIRING THE WIRING CONNECTION PROCESS MAY DIFFER SLIGHTLY BETWEEN UNITS Step 7 Wrap piping and cables Before passing the piping drain hose and the signal cable through t...

Page 17: ...ire through the hole in the wall 4 Hook the top of the indoor unit on the upper hook of the mounting plate 5 Check that unit is hooked firmly on mounting by applying slight pressure to the left and ri...

Page 18: ...will not disturb others Protected from prolonged periods of direct sunlight or rain 6 Outdoor Unit Installation Serene Wall Hung Split System Installation Instructions Outdoor Unit PRIOR TO INSTALLAT...

Page 19: ...0 until it clicks in place facing the front of the unit 4 Connect a drain hose extension not included to the drain joint to redirect water from the unit during heating mode IN COLD CLIMATES In cold cl...

Page 20: ...end of each expansion bolt 5 Hammer expansion bolts into the pre drilled holes 6 Remove the nuts from expansion bolts and place outdoor unit on bolts 7 Put washer on each expansion bolt then replace t...

Page 21: ...uce vibrations and noise Step 4 Connect signal and power cables The outside unit s terminal block is protected by an electrical wiring cover on the side of the unit A comprehensive wiring diagram is p...

Page 22: ...the air tight seal of refrigerant piping connections 3 Place flare nuts on both ends of pipe Flare each end of connecting pipes 4 Connect the pipe to indoor and outdoor unit Apply a thin coat of refr...

Page 23: ...e valve Do not grip the nut that seals the service valve See Fig 7 4 USE SPANNER TO GRIP MAIN BODY OF VALVE Torque from tightening the flare nut can snap off other parts of valve 4 While firmly grippi...

Page 24: ...should be connected to the same sub circuit as the A C unit The unit s power information can be found on the rating sticker on the product 1 Prepare the cable for connection a Ensure the correct size...

Page 25: ...th a fuse to provide overcurrent protection The specifications of the fuse are printed on the circuit board such as T3 15A 250VAC T5A 250VAC etc 1 Prepare the cable for connection a Using wire strippe...

Page 26: ...uction modification and or distribution are prohibited without written consent Revision Description C WD3002 Rev Description Date By PCR ORIGINAL A4 Size Base Model No Variation Variation Code A Drawi...

Page 27: ...Ltd Reproduction modification and or distribution are prohibited without written consent Revision Description C WD3013 Rev Description Date By PCR ORIGINAL A4 Size Base Model No Variation Variation Co...

Page 28: ...roduction modification and or distribution are prohibited without written consent Revision Description C WD3014 Rev Description Date By PCR ORIGINAL A4 Size Base Model No Variation Variation Code A Dr...

Page 29: ...modification and or distribution are prohibited without written consent Revision Description C WD3015 Rev Description Date By PCR ORIGINAL A4 Size Base Model No Variation Variation Code A Drawing No D...

Page 30: ...ON OFF FUNCTION Remove jumper wire in CN46 terminal and set F2 dip switch as above in the multi function control board to use Remote ON OFF switch When the remote switch is in OFF mode the unit will...

Page 31: ...y Installer SUB MAINS CIRCUIT BREAKER 2 3 1 INDOOR UNIT Move to left or right 30 50mm 30 50mm MAINS WIRING 220 240VAC Single Phase Neutral 50Hz CONTROL WIRING 220 240VAC Single Phase Neutral 50Hz 3 2...

Page 32: ...drop during this time To indoor unit N I T R o G E N refrigerant pipes 4000 kPa leak test for 1 hour Leak Test Fig 9 1 CAUTION Use a vacuum pump and a vac stat reading lower than 500 microns and an ai...

Page 33: ...nutes then check that there has been no change in system pressure Flare nut Cap Valve body Valve stem Fig 9 2 9 Leak Test and Air Evacuation Serene Wall Hung Split System Overview OPEN VALVE STEMS GEN...

Page 34: ...lways use protective gear when charging the system DO NOT mix refrigerant types Some systems require additional charging depending on pipe lengths The standard pipe length is 15m The additional refrig...

Page 35: ...ALL WIRING MUST COMPLY WITH LOCAL AND NATIONAL ELECTRICAL CODES AND MUST BE INSTALLED BY A LICENSED ELECTRICIAN Gas Leak Checks Proper pressure test with dry nitrogen should be performed prior to air...

Page 36: ...the MODE button to scroll through the following functions one at a time COOL Select lowest possible temperature HEAT Select highest possible temperature 4 Let each function run for 5 minutes and perfo...

Page 37: ...emperature is below 17 C In this instance you can use the MANUAL CONTROL button to test the COOL function 1 Locate the MANUAL CONTROL button on the right hand side panel of the unit See Fig 10 1 2 Pre...

Page 38: ...ironment in order to maintain your system s proper operating performance High discharge pressures are good indication that the coils need cleaning When using detergent or solvents to clean the coils f...

Page 39: ...e than 1M Heat Exchanger Check for clogging by dust Check for leaks damage Clean air inlet side as necessary Straighten any bent fins using fins comb Drain Pan Condensation line Check for obstructions...

Page 40: ...w of water Clean to eliminate obstructions sludge check condition of drain line Pour water to ensure free flow Compressor Check for high low pressure Measure insulation resistance Check compressor for...

Page 41: ...Page 41 Notes Serene Wall Hung Split System...

Page 42: ...Page 42 Notes Serene Wall Hung Split System...

Page 43: ...Page 43 Notes Serene Wall Hung Split System...

Page 44: ...actronair com au 1300 522 722 Copyright 2016 Actron Engineering Pty Limited ABN 34 002 767 240 Registered Trade Marks of Actron Engineering Pty Limited Installation Document 9590 5000 Ver 5 190325...

Reviews: