7.3 Installing the release cable
1.
Insert the end of the cable with the stop into the
guide tube at door
-
end of the motor unit, push
the cable through until you can see it in the
opening where the lever is. Insert the
stop through the release lever and
engage the lever (lock the DoorLIFT).
With the lever engaged, push the cable
50mm
further into the motor. You can
temporarily hold the cable
50mm
past
the lever with masking tape to keep it
from moving.
2.
Slide the cable sleeve over the cable and 50mm
into the guide tube in the motor housing.
3.
Mark the sleeve 25mm below the door
connector plate. Remove the sleeve and cut it
on the mark. DO NOT CUT THE CABLE. Slide the
sleeve back over the cable and into the motor
housing tube.
50 mm