6
DoorLIFT DL
-
6
Remote door system
1.
In case the track will be
mounted to
roof bows
a reinforcement (A) at the
header (above the roller shutter) could
be necessary, as forces applied upwards
can go up to 1000N. In worse case, it
can lift the roof.
2.
Never glue the complete track against
the roof. In case of installation errors or
future repairs, it should be possible to
disconnect the track from the roof.
3.
Keep a minimum clearance of 700 mm
behind the track! This because for a
proper service to the system the motor
unit needs to be removed from the
track. This only can be done by
removing the rear cover and slide the
700 mm long motor unit out of the
track.
Note:
If the length of the aluminium
track needs to be reduced, the cut must
be made at rear of the track (furthest
from the door opening). The shortest
length of track required, to operate
properly is: door 92 cm.
4.
Shutter door reinforcement is needed in
case of a plastic type door or a thin
wooden door. Consult with your doorlift
supplier if this is needed on your roll
-
up
door.
2.4 Body specific requirements
As every vehicles body is different, your Doorlift supplier can not be responsible for the body specific mechanical
connections to roof and shutter door. Although we strongly suggest:
A
700 mm
Installation guide