background image

                                                                 http://www.advancedactuators.com 

NextBolt User Manual 
For support contact us a 1-800-408-7101 ext. 102 

18 

 
 

 

 

 

 
 

 

 
 
4) Insert the tail piece into the vertical  
     retaining slot of the indoor unit. 
 
5) Gently finish joining the outdoor and  
     indoor units together.  
.  
 

          www.BuilderDepot.com

Summary of Contents for NextBolt

Page 1: ... deadbolt Please read the documentation carefully before installation use The manual details all installation procedures and operation steps Manufacturer and or Distributors of the Actuator Systems NextBolt will not be responsible for any damages caused by incorrect installation or mishandling of the lock Any such damages will void manufacturer s warranty www BuilderDepot com ...

Page 2: ...h 11 4 4 Installation of the Outdoor Unit 13 4 5 Installation of the Indoor Unit 16 5 Trouble Shooting 23 Operation Manual 25 Section I Enrolling Administrators 29 Section II Enrolling Fingerprint Users 2 thru 99 31 Section III Deleting Individual Fingerprint Users 35 Section IV Deleting ALL Fingerprint Users 37 Section V Unlocking the Actuator Systems NextBolt from outside 39 Section VI Locking t...

Page 3: ... Parts Please familiarize yourself with all the parts in the packaging box of the Actuator Systems NextBolt If any part is missing or damaged contact our service center or your local dealer Outdoor Unit Indoor Unit Strike Lining Box Indoor and Outdoor Rubber Gaskets Strike Plate Keys www BuilderDepot com ...

Page 4: ... User Manual For support contact us a 1 800 408 7101 ext 102 4 Deadbolt Latch 2 backset 70mm Deadbolt Latch 2 3 8 backset 60mm Screws 90 mm Screws 2 x 18 mm 1 x 29mm Wooden Metal Screws Alkaline Batteries 1 Fixing Plate www BuilderDepot com ...

Page 5: ...it Installation is quick and easy If your door has an existing deadbolt you only need the following tools Philips flat head screw drivers 3 Pre installation 3 1 Mark and bore holes on the door 3 11 Mark holes on door For doors with existing deadbolt lock with 2 1 8 diameter hole 1 Remove existing cylindrical deadbolt www BuilderDepot com ...

Page 6: ... use the included clear installation template when installing the Actuator Systems NextBolt on a door with an existing deadbolt 3 Rest the installation template on the front of the door on top of the existing 2 1 8 hole making sure that it is aligned properly for the door s existing 2 3 8 or 2 backset www BuilderDepot com ...

Page 7: ...y the template to the edge of the door bevel Mark the center point of the cylinder hole on the door face and then mark the center point of the deadbolt hole on door edge as indicated on the template B For installation of combination set door handle and deadbolt it is recommended that the distance is 5 between the two center points C Mark the center points of the two small holes on the door face fo...

Page 8: ...t is recommended to bore this hole from both sides of the door to avoid splintering B Bore a 1 diameter hole in the center of door edge for deadbolt 3 2 Deadbolt Latch Selection There are two deadbolt latches in each box one with a 2 3 8 60mm backset and the other with a 2 70mm backset Make sure which length you will need and select the right one before installation www BuilderDepot com ...

Page 9: ...e hole in the edge of the door follow the UP sign keeping it parallel to the face of the door Mark the outline of the face plate and remove the deadbolt B Then chisel 1 8 deep rectangular shape per your marking or until the faceplate is flush with the door edge C Insert the deadbolt latch make sure the deadbolt UP sign is facing upwards Then fasten the screws www BuilderDepot com ...

Page 10: ...from one side of the door jamb and then mark the vertical center lines 3 Extend the vertical center line and the horizontal line to mark the drill center point for the strike B Bore a 1 diameter and 1 deep hole in the door jamb at the center point for strike To ensure the proper deadbolt function this hole must be drilled at least 1 deep C Chisel the door jamb at 1 16 deep for the strike plate whi...

Page 11: ...cluded with the Actuator Systems NextBolt for 1 3 8 1 1 and 2 thick doors Your door thickness and length of the tailpiece being used must match exactly EX If your door is 1 thick then you must use the 1 long tailpiece The Actuator Systems NextBolt comes with the 1 tailpiece pre installed If your door is not 1 thick but the thickness matches one of the other pre cut tailpieces included with the loc...

Page 12: ...OUR EXACT DOOR THICKNESS If you need to trim the tailpiece be sure to measure the exact thickness of your door mark the tailpiece with a marker where it needs to be cut and trim the tail piece accordingly per the exact thickness of your door with a hacksaw or metal cutters Notes The motor could be dislodged if the tailpiece is not cut properly and is too long due to excessive pressure Warranty wil...

Page 13: ...com NextBolt User Manual For support contact us a 1 800 408 7101 ext 102 13 4 4 Installation of the Outdoor Unit 1 Attach the rubber gasket to the back of the outdoor unit 2 Make sure the deadbolt is engaged www BuilderDepot com ...

Page 14: ... advancedactuators com NextBolt User Manual For support contact us a 1 800 408 7101 ext 102 14 3 Make sure the tail piece is vertical 4 Insert tail piece through the cross slot of the latch www BuilderDepot com ...

Page 15: ...e connector and wire through the cylinder hole below the deadbolt latch 6 On the INSIDE side of the door screw the fixing plate to the outside door lock using the two 90mm screws You can break off the screws to the needed length depending on your required thickness Insure these have a snug fit www BuilderDepot com ...

Page 16: ...e firmly fastened to the outside of the door This will make it much easier and simpler to attach the inside portion of the lock 1 Select the proper door opening orientation on the back plate of the Indoor Unit If the door is left handed please push the orientation selector switch to L position if it s right handed switch the selector to R position www BuilderDepot com ...

Page 17: ...t contact us a 1 800 408 7101 ext 102 17 2 Plug wire set into circuit board making sure all prongs are firmly seated Make sure the black dots on the cable and connector align 3 Turn the manual turn knob to the vertical position facing downward www BuilderDepot com ...

Page 18: ... NextBolt User Manual For support contact us a 1 800 408 7101 ext 102 18 4 Insert the tail piece into the vertical retaining slot of the indoor unit 5 Gently finish joining the outdoor and indoor units together www BuilderDepot com ...

Page 19: ...ancedactuators com NextBolt User Manual For support contact us a 1 800 408 7101 ext 102 19 6 Fasten the two shorter 15mm screws through the fixing plate on the upper section of the inside unit www BuilderDepot com ...

Page 20: ...For support contact us a 1 800 408 7101 ext 102 20 7 Fasten the two long screws through the bottom fixing post holes on the inside unit 8 Move the manual turn knob back and forth to ensure that deadbolt opens and closes mechanically www BuilderDepot com ...

Page 21: ...http www advancedactuators com NextBolt User Manual For support contact us a 1 800 408 7101 ext 102 21 9 Insert 4 high quality AA batteries www BuilderDepot com ...

Page 22: ...n it to the vertical position locked position It should turn freely If and when the inside and outside locks are attached securely and the inside knob doesn t turn freely see the trouble shooting table below for possible solution If the knob turns freely continue with the next step Try to lock and unlock from outside by fully opening and closing the sliding cover Try to lock and unlock from inside...

Page 23: ... turn knob does not turn or turns very sluggishly 1 Incorrect installation 2 Incorrect tailpiece length 1 Make sure the tail piece was inserted vertically through the cross slot of the deadbolt and slot of the indoor unit while the turn knob was vertical facing down 2 Measure the door thickness and swap or trim the tail piece per section 4 3 of the installation manual www BuilderDepot com ...

Page 24: ...on facing down 2 Contact the Actuator Systems NextBolt dealer that you purchased to lock from OR Contact us at support advancedactuators com The sliding cover is fully lifted to power on without any fingerprint enrolled inside the deadbolt does not disengage or four alert beeps are heard 1 Right left hand door configurations is set incorrectly 2 The tail piece was not set properly 1 Correctly conf...

Page 25: ...uring daily use nothing happens fingerprint scanner does not blink 1 Batteries not inserted correctly 2 Wires not connected properly 1 Remove reinsert the batteries following and signs in the battery house 2 Check the connections and make sure wires are fully plugged in Six beeps are heard when any function is performed Low Voltage Change the batteries Operation Manual Operation Manual Helpful Hin...

Page 26: ...ration was successful Short Double Beep Indicates that individual fingerprint user deletion sequence has begun Long Double Beep Indicates that Delete All programming was successful Four Beeps Indicates unsuccessful enrollment unsuccessful verification attempt OR Actuator Systems NextBolt was improperly installed see Installation Guide Five Beeps Indicates the selected user was unsuccessfully delet...

Page 27: ...ssure when placing the finger on the scanner gives the best image but the finger must not move during scanning Moist fingers provide better images than dry ones If on cold dry days you have difficulty for example try moistening your finger with your breath or a little lotion Very dry dirty or scarred fingers are obviously not recommended since they will obscure the fingerprint The pointer finger i...

Page 28: ...s in direct sunlight be sure to shade the sensor with your shadow so sunlight will not reflect off of the mirror in the sensor Important Programming Notes When Adding or Deleting Fingerprints the closed sliding cover must be fully lifted within 8 seconds after pressing the ADD or DEL button or the NextBolt will power off If this occurs simply close the sliding cover press the ADD or DEL button aga...

Page 29: ...or not to program the lock Section I Enrolling Administrators First Fingerprint User Sliding cover must be closed before any programming sequence can begin As noted in the Helpful Hints section the first two users that enroll their fingerprints into the Actuator Systems NextBolt will automatically be programmed as ADMINISTRATORS Users 1 and 2 ADMINISTRATORS can apply all programming functions as w...

Page 30: ...Keep your pointer finger on the scanning window thru all three scans After the scanning is completed you will hear one of the following o Single long beep indicating that the operation was successful OR o Four beeps indicating that your fingerprint was not successfully enrolled If you hear four beeps please start the enrollment process over from the beginning Fully open the sliding cover located o...

Page 31: ...ore any programming sequence can begin As noted in the Helpful Hints section the third thru ninety ninth fingerprint users enrolled Users 3 thru 99 are automatically programmed at the USER level USER level fingerprints can only be used to unlock the door not to program the lock Please use the following steps to enroll additional fingerprint users Users 3 thru 99 Close the sliding cover www Builder...

Page 32: ...ators com NextBolt User Manual For support contact us a 1 800 408 7101 ext 102 32 Remove the battery cover from the indoor unit Press the ADD button located on the indoor unit Single beep will be heard www BuilderDepot com ...

Page 33: ... the fingerprint sensor will power on After the fingerprint sensor powers on rest an ADMINISTRATOR S finger on the sensor window to verify that they are an Administrator When the first Administrator s fingerprint is successfully verified the sensor will briefly turn off for less than one second Immediately remove the ADMINSTRATOR S finger and enter the KEPRESS SEQUENCE for the user number you wish...

Page 34: ...nning is completed you will hear one of the following o Single long beep indicating that the operation was successful OR o Four beeps indicating that your fingerprint was not successfully enrolled If you hear four beeps please start the enrollment process over from the beginning Once enrollment begins users can be enrolled consecutively without the need to verify the administrator again After you ...

Page 35: ...closed before any programming sequence can begin The Individual Fingerprint User Deletion programming function deletes the individual user you select from your enrolled users Please use the following steps to delete individual fingerprint users With the battery cover removed press the DEL button located on the indoor unit Short Double Beep will be heard www BuilderDepot com ...

Page 36: ...d and the fingerprint sensor will power on Rest an Administrator s fingerprint on the scanning window When the LED light goes out enter the keypress sequence The chart is in Appendix A of this manual o If you hear four beeps this indicates that the Administrator was not recognized If you hear five beeps this indicates the user deletion was not successful Begin again from the first step of Section ...

Page 37: ... be closed before any programming sequence can begin Deleting ALL enrolled fingerprint users will reset the lock and all users including Administrators fingerprints will be deleted With no fingerprints enrolled in the Actuator Systems NextBolt the deadbolt will engage disengage when the sliding cover is fully opened and immediately closed Close the sliding cover Repeat steps from the beginning of ...

Page 38: ...ADD OPEN CLOSE Now all three buttons on the lock will be held down 3 When one long beep is heard pull the outside cover up and place the Admin finger on the sensor for verification when the sensor light turns on 4 Once one long beep is heard the lock is reset successfully Close the sliding cover IMPORTANT SECURITY NOTE WITHOUT ANY FINGERPRINTS ENROLLED THE NEXTBOLT WILL LOCK AND UNLOCK BY FULLY OP...

Page 39: ...locking the Actuator Systems NextBolt from outside In case of emergency override keys can be used to disengage the deadbolt Please use the following steps to unlock the Actuator Systems NextBolt from outside with your enrolled fingerprint Fully lift the sliding cover located on the outdoor unit www BuilderDepot com ...

Page 40: ...erify If fingerprint verification is successful the deadbolt will disengage and a single short beep will be heard If verification of enrolled fingerprint was not successful then 4 short beeps will be heard If this happens the fingerprint scanner will still turn on two additional times enabling users to try more If all the two additional verification attempts still fail please start the unlocking p...

Page 41: ... 7101 ext 102 41 Section VI Locking the Actuator Systems NextBolt from Outside In case of emergency override keys can be used to engage the deadbolt Please use the following steps to lock the Actuator Systems NextBolt from outside when leaving Close the sliding cover www BuilderDepot com ...

Page 42: ...Systems NextBolt from Inside In case of emergency manual turn knob can be used to disengage the deadbolt Please use the following steps to lock and unlock the Actuator Systems NextBolt from inside Make sure your door is closed Open and immediately close the sliding cover Deadbolt will engage and a single short beep will be heard www BuilderDepot com ...

Page 43: ...port Contact the Actuator Systems NextBolt dealer that you purchased the lock from OR Contact us at support advancedactuators com for additional support Press the OPEN CLOSE button located between the ADD and DEL buttons Deadbolt will engage disengage and single short beep will be heard www BuilderDepot com ...

Page 44: ...DD DEL ADD 6 ADD ADD DEL 7 ADD ADD ADD 8 ADD DEL DEL DEL 9 ADD DEL DEL ADD 10 ADD DEL ADD DEL 11 ADD DEL ADD ADD 12 ADD ADD DEL DEL 13 ADD ADD DEL ADD 14 ADD ADD ADD DEL 15 ADD ADD ADD ADD 16 ADD DEL DEL DEL DEL 17 ADD DEL DEL DEL ADD 18 ADD DEL DEL ADD DEL 19 ADD DEL DEL ADD ADD 20 ADD DEL ADD DEL DEL 21 ADD DEL ADD DEL ADD 22 ADD DEL ADD ADD DEL 23 ADD DEL ADD ADD ADD 24 ADD ADD DEL DEL DEL 25 A...

Page 45: ... DEL DEL 37 ADD DEL DEL ADD DEL ADD 38 ADD DEL DEL ADD ADD DEL 39 ADD DEL DEL ADD ADD ADD 40 ADD DEL ADD DEL DEL DEL 41 ADD DEL ADD DEL DEL ADD 42 ADD DEL ADD DEL ADD DEL 43 ADD DEL ADD DEL ADD ADD 44 ADD DEL ADD ADD DEL DEL 45 ADD DEL ADD ADD DEL ADD 46 ADD DEL ADD ADD ADD DEL 47 ADD DEL ADD ADD ADD ADD 48 ADD ADD DEL DEL DEL DEL 49 ADD ADD DEL DEL DEL ADD 50 ADD ADD DEL DEL ADD DEL 51 ADD ADD DE...

Page 46: ...DEL DEL ADD DEL DEL 69 ADD DEL DEL DEL ADD DEL ADD 70 ADD DEL DEL DEL ADD ADD DEL 71 ADD DEL DEL DEL ADD ADD ADD 72 ADD DEL DEL ADD DEL DEL DEL 73 ADD DEL DEL ADD DEL DEL ADD 74 ADD DEL DEL ADD DEL ADD DEL 75 ADD DEL DEL ADD DEL ADD ADD 76 ADD DEL DEL ADD ADD DEL DEL 77 ADD DEL DEL ADD ADD DEL ADD 78 ADD DEL DEL ADD ADD ADD DEL 79 ADD DEL DEL ADD ADD ADD ADD 80 ADD DEL ADD DEL DEL DEL DEL 81 ADD D...

Page 47: ...D ADD DEL DEL ADD 90 ADD DEL ADD ADD DEL ADD DEL 91 ADD DEL ADD ADD DEL ADD ADD 92 ADD DEL ADD ADD ADD DEL DEL 93 ADD DEL ADD ADD ADD DEL ADD 94 ADD DEL ADD ADD ADD ADD DEL 95 ADD DEL ADD ADD ADD ADD ADD 96 ADD ADD DEL DEL DEL DEL DEL 97 ADD ADD DEL DEL DEL DEL ADD 98 ADD ADD DEL DEL DEL ADD DEL 99 ADD ADD DEL DEL DEL ADD ADD www BuilderDepot com ...

Page 48: ... com NextBolt User Manual For support contact us a 1 800 408 7101 ext 102 48 USER ENROLLMENT TABLE Number Name Finger Used L R Date 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 www BuilderDepot com ...

Reviews: