background image

5

PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE 

WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.

BATTERY SAFETY: Clean the battery contacts and also those of the device prior to battery installation. Remove batteries from equipment which is not to be 

used for an extended period of time. Follow the polarity (+/-) diagram in the battery compartment. Promptly remove dead batteries from the device. Dispose of used 

batteries properly. Only batteries of the same or equivalent type as recommended are to be used. DO NOT incinerate used batteries. DO NOT dispose of batteries in fire, 

as batteries may explode or leak. DO NOT mix old and new batteries or types of batteries (alkaline/standard). DO NOT use rechargeable batteries. DO NOT recharge 

non-rechargeable batteries. DO NOT short-circuit the supply terminals.

Display Unit Setup

Set the A-B-C Switch

 Locate the A-B-C switch inside 

the battery compartment. Set 

the A-B-C switch to A, B or C. 

You must select the same letter 

choices for both the display unit 

and the sensor in order for the 

units to synchronize. 

Install or Replace Backup 

Batteries

1.  Remove the battery  

compartment cover.

2.  Insert 3 x AA alkaline batteries 

into the battery compartment, 

as shown. Follow the polarity 

(+/–) diagram in the battery 

compartment. 

3. Replace the battery cover.

1

2

2

Install Batteries 

3 AA batteries

1

A-B-C Switch 

set to match 

sensor

A B C

Summary of Contents for 00529W

Page 1: ... 2 Product Registration 2 Features Benefits Sensor 2 Features Benefits Display 3 Setup 4 Sensor Setup 4 Display Setup 5 Intelli Time Clock 6 Set the Time Date Units 6 Placement Guidelines 7 Using the Thermometer 8 Troubleshooting 9 Care Maintenance 10 Replace Intelli Time Battery 10 Specifications 10 FCC Information 10 Customer Support 11 Warranty 11 Thermometer models 00592W 00592A ...

Page 2: ...lay unit with tabletop stand 2 Outdoor Sensor 3 Instruction Manual PRODUCT REGISTRATION Register online to receive 1 year warranty protection www AcuRite com IMPORTANT PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE Register a Product Features Benefits 4 3 2 1 5 OUTDOOR SENSOR 1 Integrated Hanger For easy placement 2 Wireless Signal Indicator Flashes when data is being sent to the display u...

Page 3: ...9 high Button Press to display highest temperature recorded since midnight 10 low Button Press to display lowest temperature recorded since midnight 11 Current Indoor Humidity 12 Display Low Battery Icon 13 Sensor Signal Strength 14 Sensor Low Battery Icon DISPLAY UNIT BACK 15 Reset Button Full reset to factory defaults 16 A B C Switch ID code that must match sensor s A B C switch to ensure units ...

Page 4: ...rechargeable batteries are not recommended The sensor requires lithium batteries in low temperature conditions Cold temperatures can cause alkaline batteries to function improperly Use lithium batteries in the sensor for temperatures below 4ºF 20ºC 1 Slide off the battery compartment cover Take note of the A B C switch setting inside the battery compartment for display unit setup 2 Insert 2 x AA b...

Page 5: ...es in fire as batteries may explode or leak DO NOT mix old and new batteries or types of batteries alkaline standard DO NOT use rechargeable batteries DO NOT recharge non rechargeable batteries DO NOT short circuit the supply terminals Display Unit Setup Set the A B C Switch Locate the A B C switch inside the battery compartment Set the A B C switch to A B or C You must select the same letter choi...

Page 6: ...g will blink on the display To adjust the currently selected flashing item press and release the Up or Down buttons press and HOLD to fast adjust To save your adjustments press and release the Set button again to adjust the next preference The preference set order is as follows TIME ZONE PST MST CST EST AST HAST AKST DST Daylight Saving Time ON or OFF CLOCK HOUR CLOCK MINUTE CALENDAR MONTH CALENDA...

Page 7: ...location like a well covered tree branch The best location is 4 to 8 feet above the ground with permanent shade and plenty of fresh air to circulate around the sensor Important Placement Guidelines To ensure accurate temperature measurement place units out of direct sunlight and away from any heat sources or vents Display unit and outdoor sensor must be within 330 ft 100 m of each other To maximiz...

Page 8: ...orded value press and hold the low or high button for 2 seconds to manually clear the currently displayed recorded values The LOW and HIGH recorded values will automatically clear and reset at 12 00 am midnight every day Moon Phase This weather station features a moon phase window which will automatically display the current moon phase provided the calendar is set properly OPERATION ...

Page 9: ...utton located in the battery compartment of the display unit Date and time will need to be entered after a reset Outdoor temperature is flashing or showing dashes Flashing of the outdoor temperature is generally an indication of wireless interference 1 Bring both the sensor and display unit indoors and remove at least one battery from each 2 Make sure the A B C switch on both units match 3 Reinsta...

Page 10: ...2 This device must accept any interference received including interference that may cause undesired operation WARNING Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of ...

Page 11: ...ies are hereby expressly disclaimed including without limitation the implied warranty of merchantability and the implied warranty of fitness for a particular purpose Chaney expressly disclaims all liability for special consequential or incidental damages whether arising in tort or by contract from any breach of this warranty Some states do not allow the exclusion or limitation of incidental or con...

Page 12: ... AcuRite uses patented technology Visit www AcuRite com patents for details Printed in China 00592A4 INST 092914 It s more than accurate it s AcuRite offers an extensive assortment of precision instruments designed to provide you with information you can depend on to Plan your day with confidence www AcuRite com Weather Stations Temperature Humidity Weather Alert Radio Kitchen Thermometers Timers ...

Reviews: