background image

18

19

If your AcuRite product does not operate properly after trying 

the troubleshooting steps, visit www.AcuRite.com or call  

(877) 221-1252 for assistance.

Problem

Possible Solution

Cannot access data

online or on the 

AcuRite mobile app

• Verify that the status in the AcuRite Connect software 

on your PC indicates that data was uploaded OK.

• Verify that you created an account or logged into 

an existing account at www.acu-link.com or in the 

AcuRite app, and that you input the display’s MAC 

ADDRESS as a part of the account setup.

• Verify that the USB cable is securely connected to the 

display AND to the PC.

• Verify the display is powered ON.
• Verify the PC that the display is connected to is 

always powered ON.

• Verify the PC that the display is connected to is 

always connected to the internet.

• Verify that the display’s MAC ADDRESS is entered 

correctly in the AcuRite Connect software on your PC.

• Verify that “Streaming” is enabled in the AcuRite 

Connect software on your PC.

• Verify that the display’s MAC ADDRESS is correct in 

your www.acu-link.com and/or AcuRite mobile app 

account.

• Follow on-screen troubleshooting steps in the AcuRite 

Connect software.

AcuRite Connect data 

is different than the 

display’s data

• Check that the USB cable is securely connected to the 

display AND to the PC’s USB port.

• Restart the AcuRite Connect software.
• Unplug the USB cable from the PC for 1 minute, and 

then plug the cable back in again.

• USB port may be malfunctioning, try using another 

USB port.

Troubleshooting

Care & Maintenance

Display Unit Care

Clean with a soft, damp cloth. Do not use caustic cleaners or abrasives. Keep away 

from dust, dirt and moisture. Clean ventilation ports regularly with a gentle puff of air.

5-in-1 Sensor Care

Clean the Sensor

Clean with a soft damp cloth. Do not use caustic cleaners or abrasives that will mar the 

polished surfaces of the rain collection funnel or the solar cell. Scratches will result in 

decreased performance and reliability.

Insect Prevention 

Insects may cause obstructions and interrupt data by nesting in or on the 5-in-1 sensor. 

To limit this problem, spray sensor with a household insect repellent. Consult the insect 

repellent instructions prior to use.

Snow & Freezing Weather

The 5-in-1 sensor will not be damaged by freezing conditions. NOTE: If the rain collec-

tor cup fills with snow and then melts, it will register as rain on the display unit.

Clean the Rain Collector Cup
 

Remove and empty  rain collector debris filter. The debris filter is located in the rain col-

lector funnel. Remove from the top by gently squeezing and pulling out.

Clean the Wind Vane & Anemometer

Remove foreign matter from the outside of the sensor for free movement of the wind 

vane and anemometer. If needed, use a small amount of spray lubricant, clear silicone 

or graphite powder on the anemometer for improved movement.

Calibration

The indoor and outdoor temperature and humidity readings, and barometric 

pressure can be calibrated on the display unit to improve accuracy. Calibration 

can improve accuracy when sensor placement or environmental factors impact 

the data accuracy.
1. To access calibration mode, press AND HOLD the “

 

”, “   ”, and “

  

” 

buttons simultaneously for at least 5 seconds.

2. To adjust the currently selected (flashing) item, press and release the “

 

“ 

or “

  

“ buttons to calibrate the data value higher or lower from the actual 

reading.

3. To save your adjustments, press and release the “   ” button to adjust the 

next preference. The “ ” icon will remain illuminated next to calibrated 

values.

  The preference set order is as follows: 

OUTDOOR TEMPERATURE 

OUTDOOR HUMIDITY 

Summary of Contents for 02064C

Page 1: ...Features Benefits Display 4 Setup 7 5 in 1 Sensor Setup 7 Display Unit Setup 8 AcuRite Connect 9 Set the Time Date Units 10 Backlight Settings 10 Placement Guidelines 11 5 in 1 Sensor Installation 12 Using the Weather Center 13 Rainfall Tracking 14 Weather Ticker 15 Troubleshooting 16 Care Maintenance 19 Calibration 20 Specifications 21 FCC Information 21 Customer Support 22 Warranty 22 Profession...

Page 2: ...ion www AcuRite com IMPORTANT PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE Register a Product 7 2 1 8 10 5 6 11 4 3 5 in 1 SENSOR 1 Rainfall Collector Funnel 2 Solar Cell Panel Converts sunlight into power to run internal aspirating fan Internal Aspirating Fan not shown Draws ambient air into sensor to reduce solar radiation heating resulting in more accurate temperature measurement 3 A ...

Page 3: ...casting pulls data from your 5 in 1 sensor to generate your personal forecast 17 Rainfall History Displays historical rainfall totals see page 14 18 Barometric Pressure Arrow icon indicates direction pressure is trending 19 Button Changes the rainfall data being displayed 17 20 Button For setup preferences and manually cycling through Weather Ticker messages 21 Button for setup preferences 22 Butt...

Page 4: ... in the 5 in 1 sensor for temperatures below 4ºF 20ºC 1 Slide off the battery compartment cover 2 Insert 4 x AA batteries into the battery compartment as shown Follow the polarity diagram in the battery compartment 3 Replace the battery cover Remove Rain Gauge Stabilizer Locate and remove the rain gauge stabilizer plastic tab taped into the bottom of the sensor The rain gauge will not function unt...

Page 5: ... IMPORTANT Batteries are a backup power source to preserve records in the event of a power outage Power adapter is the recommended primary power source to enjoy the full functionality of this product 2 Plug in Power Adapter AcuRite Connect AcuRite Connect works with Windows PC s to provide access to your Weather Center data in the following ways Data File Display unit logs or stores data so that y...

Page 6: ... to ensure accurate wind measurement Visit us online to view installation photos and video or learn more about AcuRite technology www AcuRite com 5in1 View Video Set the Time Date Units Press the button located on the front of the display unit to enter SET MODE Once in set mode the preference you are currently setting will blink on the display To adjust the currently selected flashing item press a...

Page 7: ...e The 5 in 1 sensor will now synchronize with the display unit It may take a few minutes for synchronization to complete If both or one of the units appear to be functioning improperly please refer to the troubleshooting section SOUTH 1 5 meters NO OBSTRUCTIONS ABOVE OR AROUND OPERATION Using the Professional Weather Center Learning Mode Self Calibrating Forecasting use a unique algorithm to analy...

Page 8: ...TEMP XX MM DD ALL TIME HIGH TEMP XXX RECORDED MM DD YY ALL TIME LOW TEMP XXX RECORDED MM DD YY 24 HOUR TEMP CHANGE XX ALL TIME HIGH WIND XX MPH RECORDED MM DD YY 7 DAY AVERAGE WIND XX MPH TODAY S AVERAGE WIND XX MPH MOON NEW MOON WAXING CRESCENT MOON FIRST QUARTER MOON WAXING GIBBOUS MOON FULL MOON WANING GIBBOUS MOON LAST QUARTER MOON WANING CRESCENT INDOOR HUMIDITY OK INDOOR HUMIDITY HIGH INDOOR...

Page 9: ...e before forecast and pressure will be accurate Allow unit to run continuously for 33 days Battery removal or resetting the display unit will restart Learning Mode After 14 days forecast should be fairly accurate however Learning Mode calibrates for a total of 33 days Troubleshooting Problem Possible Solution Inaccurate temperature or humidity Make sure both the display unit and 5 in 1 sensor are ...

Page 10: ...a gentle puff of air 5 in 1 Sensor Care Clean the Sensor Clean with a soft damp cloth Do not use caustic cleaners or abrasives that will mar the polished surfaces of the rain collection funnel or the solar cell Scratches will result in decreased performance and reliability Insect Prevention Insects may cause obstructions and interrupt data by nesting in or on the 5 in 1 sensor To limit this proble...

Page 11: ...ct to the following two conditions 1 This device may NOT cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against ha...

Page 12: ...ties are hereby expressly disclaimed including without limitation the implied warranty of merchantability and the implied warranty of fitness for a particular purpose Chaney expressly disclaims all liability for special consequential or incidental damages whether arising in tort or by contract from any breach of this warranty Some states do not allow the exclusion or limitation of incidental or co...

Page 13: ...s AcuRite uses patented technology Visit www AcuRite com patents for details Printed in China 02064C INST 052215 It s More than Accurate it s AcuRite offers an extensive assortment of precision instruments designed to provide you with information you can depend on to Plan your day with confidence www AcuRite com Weather Stations Temperature Humidity Weather Alert Radio Kitchen Thermometers Timers ...