background image

20

21

INDOOR TEMPERATURE 

INDOOR HUMIDITY 

BAROMETRIC PRESSURE  (must be set to MANUAL mode to calibrate)*

  *To change from AUTO to MANUAL pressure mode and vice versa, press 

AND HOLD the “    ” button for 5-7 seconds. The display indicates the 

current pressure mode selected, “AUTO” or “MANUAL”. The “    ” icon will 

appear next to the barometric pressure to indicate that MANUAL mode has 

been activated. Press and HOLD the “     ” button for 5-7 seconds to return 

to AUTO mode. 

After 5-10 seconds of inactivity, the display will save the adjustments and exit 

calibration mode. Note: Calibrations will be erased if the display is reset or if 

batteries are removed and the power adapter is unplugged. 

Calibrate the Rain Gauge

The rain gauge on the 5-in-1 sensor can be calibrated to improve accuracy. 

Items Needed

: 5-in-1 sensor, display unit, plastic cup, pin, screw driver

1. First, ensure 5-in-1 sensor is perfectly level using built-in bubble level.
2. Place display unit close so you can monitor it during calibration.
3. Make a pin hole in the bottom of a plastic cup. Hold the cup over the rain gauge and 

fill it with exactly 1 cup (8oz) of water, allowing the water to drip into the rain gauge. 

You should hear the internal buckets tip and see water drain through the rain gauge.

4. A few seconds after each bucket tip, the display unit displays rainfall in 

approximately 0.01” or more increments.

5. The cup of water should take more than 20 minutes to empty; a quicker period will 

result in inaccurate calibration. Try to simulate a normal steady rainfall. When cup is 

empty of water, display unit should register 1.06”

Tips

• There should be nearly an equal number of water drops (about 25 water drops) 

between bucket tips. If not, adjust the calibration screws on the bottom of the 5-in-1 

sensor until an equal number of water drops are tipping the buckets. Then, restart the 

calibration procedure.

• If you don’t hear the buckets tipping and see water dripping alternately out of 

each drain, there may be an issue with the rain gauge or it’s adjustment. See 

Troubleshooting on page 18.

Adjustment

If the rain gauge doesn’t register close to 1.06”, make an EQUAL adjustment to the two 

calibration screws on the bottom of the 5-in-1 sensor. Turning screws clockwise increases 

rainfall; counter clockwise decreases rainfall.
• To adjust the rainfall reading by 2% turn both screws 1/8  of a turn.  

• To adjust the rainfall reading by 4% turn both screws 1/4 of a turn.  

• To adjust the rainfall reading by 8% turn both screws 1/2 of a turn.

Watch the video at www.acurite.com/5in1

FCC Information

This device complies with part 15 of FCC rules. Operation is subject to the following two conditions:
1- This device may NOT cause harmful interference, and
2- This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed 
to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency 
energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no  
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which 
can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could 
void the user authority to operate the equipment.
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation of the device.

Specifications

TEMPERATURE RANGE

Outdoor: -40

º

F to 158

º

F; -40

º

C to 70

º

C

Indoor: 32

º

F to 122

º

F; 0

º

C to 50

º

C

HUMIDITY RANGE

Outdoor: 1% to 99%
Indoor: 1% to 99%

WIND SPEED

0 to 99 mph; 0 to 159 kph

WIND DIRECTION  

INDICATORS 

16 points

RAINFALL

0 to 3937 in; 0 to 99999mm

WIRELESS RANGE

330ft / 100m 

depending on home construction materials

OPERATING FREQUENCY

433 MHz

POWER

Display: 4.5V AC, 250mA adapter

             3 x AA alkaline batteries (optional)
Sensor: 4 x AA alkaline or lithium batteries

DATA REPORTING

Wind Speed: 18 second updates; Direction: 30 seconds

Outdoor temperature & humidity: 36 second updates

Indoor temperature & humidity: 60 second updates

AcuRite Connect CSV Data Logging: 12 minute intervals

AcuRite Connect to AcuRite Software/App: 18 seconds

DISPLAY UNIT MEMORY

512 kilobytes (not expandable)

ACURITE CONNECT SYSTEM  

REQUIREMENTS

Windows 8.1 / 8 / 7; 1 GHz or faster processor; 1 GB 

(32-bit) or 2 GB (64-bit) of RAM; available USB port

High speed internet is required for some advanced 

features of AcuRite Connect, such as the  

AcuRite software and app.

Summary of Contents for 02064C

Page 1: ...Features Benefits Display 4 Setup 7 5 in 1 Sensor Setup 7 Display Unit Setup 8 AcuRite Connect 9 Set the Time Date Units 10 Backlight Settings 10 Placement Guidelines 11 5 in 1 Sensor Installation 12 Using the Weather Center 13 Rainfall Tracking 14 Weather Ticker 15 Troubleshooting 16 Care Maintenance 19 Calibration 20 Specifications 21 FCC Information 21 Customer Support 22 Warranty 22 Profession...

Page 2: ...ion www AcuRite com IMPORTANT PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE Register a Product 7 2 1 8 10 5 6 11 4 3 5 in 1 SENSOR 1 Rainfall Collector Funnel 2 Solar Cell Panel Converts sunlight into power to run internal aspirating fan Internal Aspirating Fan not shown Draws ambient air into sensor to reduce solar radiation heating resulting in more accurate temperature measurement 3 A ...

Page 3: ...casting pulls data from your 5 in 1 sensor to generate your personal forecast 17 Rainfall History Displays historical rainfall totals see page 14 18 Barometric Pressure Arrow icon indicates direction pressure is trending 19 Button Changes the rainfall data being displayed 17 20 Button For setup preferences and manually cycling through Weather Ticker messages 21 Button for setup preferences 22 Butt...

Page 4: ... in the 5 in 1 sensor for temperatures below 4ºF 20ºC 1 Slide off the battery compartment cover 2 Insert 4 x AA batteries into the battery compartment as shown Follow the polarity diagram in the battery compartment 3 Replace the battery cover Remove Rain Gauge Stabilizer Locate and remove the rain gauge stabilizer plastic tab taped into the bottom of the sensor The rain gauge will not function unt...

Page 5: ... IMPORTANT Batteries are a backup power source to preserve records in the event of a power outage Power adapter is the recommended primary power source to enjoy the full functionality of this product 2 Plug in Power Adapter AcuRite Connect AcuRite Connect works with Windows PC s to provide access to your Weather Center data in the following ways Data File Display unit logs or stores data so that y...

Page 6: ... to ensure accurate wind measurement Visit us online to view installation photos and video or learn more about AcuRite technology www AcuRite com 5in1 View Video Set the Time Date Units Press the button located on the front of the display unit to enter SET MODE Once in set mode the preference you are currently setting will blink on the display To adjust the currently selected flashing item press a...

Page 7: ...e The 5 in 1 sensor will now synchronize with the display unit It may take a few minutes for synchronization to complete If both or one of the units appear to be functioning improperly please refer to the troubleshooting section SOUTH 1 5 meters NO OBSTRUCTIONS ABOVE OR AROUND OPERATION Using the Professional Weather Center Learning Mode Self Calibrating Forecasting use a unique algorithm to analy...

Page 8: ...TEMP XX MM DD ALL TIME HIGH TEMP XXX RECORDED MM DD YY ALL TIME LOW TEMP XXX RECORDED MM DD YY 24 HOUR TEMP CHANGE XX ALL TIME HIGH WIND XX MPH RECORDED MM DD YY 7 DAY AVERAGE WIND XX MPH TODAY S AVERAGE WIND XX MPH MOON NEW MOON WAXING CRESCENT MOON FIRST QUARTER MOON WAXING GIBBOUS MOON FULL MOON WANING GIBBOUS MOON LAST QUARTER MOON WANING CRESCENT INDOOR HUMIDITY OK INDOOR HUMIDITY HIGH INDOOR...

Page 9: ...e before forecast and pressure will be accurate Allow unit to run continuously for 33 days Battery removal or resetting the display unit will restart Learning Mode After 14 days forecast should be fairly accurate however Learning Mode calibrates for a total of 33 days Troubleshooting Problem Possible Solution Inaccurate temperature or humidity Make sure both the display unit and 5 in 1 sensor are ...

Page 10: ...a gentle puff of air 5 in 1 Sensor Care Clean the Sensor Clean with a soft damp cloth Do not use caustic cleaners or abrasives that will mar the polished surfaces of the rain collection funnel or the solar cell Scratches will result in decreased performance and reliability Insect Prevention Insects may cause obstructions and interrupt data by nesting in or on the 5 in 1 sensor To limit this proble...

Page 11: ...ct to the following two conditions 1 This device may NOT cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against ha...

Page 12: ...ties are hereby expressly disclaimed including without limitation the implied warranty of merchantability and the implied warranty of fitness for a particular purpose Chaney expressly disclaims all liability for special consequential or incidental damages whether arising in tort or by contract from any breach of this warranty Some states do not allow the exclusion or limitation of incidental or co...

Page 13: ...s AcuRite uses patented technology Visit www AcuRite com patents for details Printed in China 02064C INST 052215 It s More than Accurate it s AcuRite offers an extensive assortment of precision instruments designed to provide you with information you can depend on to Plan your day with confidence www AcuRite com Weather Stations Temperature Humidity Weather Alert Radio Kitchen Thermometers Timers ...

Reviews: