American Electric Lighting a division of Acuity Lighting Group, Inc. Granville, OH
DRAWING NO. A72084 REV --
(BACK)
©2008 ACUITY LIGHTING GROUP, INC.
PART NUMBER 057-71-72084
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
POST TOP LUMINAIRE 247 SERIES & TCL FULL CUTOFF (FC)
cont.
cont.
MOUNTING:
MOUNTING:
NOTE: THIS UNIT WILL ACCEPT POLE TOPS WITH AN
NOTE: THIS UNIT WILL ACCEPT POLE TOPS WITH AN
EXTERIOR DIAMETER BETWEEN 2.375” AND 3“
EXTERIOR DIAMETER BETWEEN 2.375” AND 3“
1. WHEN PLACING THE UNIT ON THE POLE, FEED THE
1. WHEN PLACING THE UNIT ON THE POLE, FEED THE
SUPPLY LEADS THROUGH THE BASE OF THE UNIT.
SUPPLY LEADS THROUGH THE BASE OF THE UNIT.
NOTE: IF UNIT IS PRE-WIRED, INSTEAD OF STEP 1, FEED
NOTE: IF UNIT IS PRE-WIRED, INSTEAD OF STEP 1, FEED
THE SUPPLIED PRE-WIRE THROUGH THE POST TOP AND
THE SUPPLIED PRE-WIRE THROUGH THE POST TOP AND
DOWN THE POLE.
DOWN THE POLE.
2. ORIENT THE UNIT SO THAT THE CLOSURE SCREW
2. ORIENT THE UNIT SO THAT THE CLOSURE SCREW
(OR TRIGGER LATCH IF EQUIPPED) ARE TO THE
(OR TRIGGER LATCH IF EQUIPPED) ARE TO THE
STREET SIDE.
STREET SIDE.
3. TIGHTEN THE THREE MOUNTING SET SCREWS.
3. TIGHTEN THE THREE MOUNTING SET SCREWS.
WIRING:
WIRING:
N
NOTE: THIS PROCEDURE IS NOT NECESSARY IF UNIT IS
OTE: THIS PROCEDURE IS NOT NECESSARY IF UNIT IS
SUPPLIED WITH PRE-WIRE.
SUPPLIED WITH PRE-WIRE.
1. OPEN THE UNIT AND REMOVE THE COVER. (SEE
1. OPEN THE UNIT AND REMOVE THE COVER. (SEE
“OPENING AND CLOSING THE UNIT” AND “COVER
“OPENING AND CLOSING THE UNIT” AND “COVER
REMOVAL & INSTALLATION” SECTION.)
REMOVAL & INSTALLATION” SECTION.)
2. LOCATE THE WIRING DIAGRAM ATTACHED TO THE
2. LOCATE THE WIRING DIAGRAM ATTACHED TO THE
INSIDE OF THE HOOD.
INSIDE OF THE HOOD.
3. USING THE WIRING DIAGRAM AS A GUIDE, CONNECT
3. USING THE WIRING DIAGRAM AS A GUIDE, CONNECT
THE POWER SUPPLY LEADS TO THE TERMINAL BLOCK.
THE POWER SUPPLY LEADS TO THE TERMINAL BLOCK.
4. CONNECT THE GREEN OR BARE GROUND SUPPLY WIRE
4. CONNECT THE GREEN OR BARE GROUND SUPPLY WIRE
TO THE CASTING BY HOOKING IT AROUND THE HEAD OF
TO THE CASTING BY HOOKING IT AROUND THE HEAD OF
THE GREEN GROUNDING SCREW, LOCATED BESIDE THE
THE GREEN GROUNDING SCREW, LOCATED BESIDE THE
TERMINAL BLOCK, AND TIGHTENING THE SCREW
TERMINAL BLOCK, AND TIGHTENING THE SCREW
SECURELY.
SECURELY.
5. REINSTALL THE COVER.
5. REINSTALL THE COVER.
6. CLOSE THE UNIT.
6. CLOSE THE UNIT.
LAMP INSTALLATION:
LAMP INSTALLATION:
11. OPEN THE
. OPEN THE HOOD OF THE
HOOD OF THE UNIT.
UNIT.
2. SECURELY INSERT LAMP INTO LAMP SOCKET.
2. SECURELY INSERT LAMP INTO LAMP SOCKET.
3. TIGHTEN LAMP WITH ENOUGH TORQUE TO FULLY
3. TIGHTEN LAMP WITH ENOUGH TORQUE TO FULLY
DEPRESS AND LOAD THE CENTER CONTACT OF THE
DEPRESS AND LOAD THE CENTER CONTACT OF THE
SOCKET.
SOCKET.
NOTE: NEMA SPECIFIES TORQUE OF 35 in-lbs.
NOTE: NEMA SPECIFIES TORQUE OF 35 in-lbs.
4. CLOSE THE UNIT.
4. CLOSE THE UNIT.
5. ENERGIZE AND VERIFY OPERATION.
5. ENERGIZE AND VERIFY OPERATION.
PHOTOCONTROL CONT:
PHOTOCONTROL CONT:
1. REMOVE THE CUPOLA CAP BY GRABBING ONE SIDE OF IT AND
1. REMOVE THE CUPOLA CAP BY GRABBING ONE SIDE OF IT AND
LIFTING UP. (SEE FIGURE 1) THE CUPOLA CAP IS VERY RIGID
LIFTING UP. (SEE FIGURE 1) THE CUPOLA CAP IS VERY RIGID
AND TIGHT, DESIGNED SO IT DOESN’T EASILY COME OFF.
AND TIGHT, DESIGNED SO IT DOESN’T EASILY COME OFF.
HOWEVER, IT MAY BE REMOVED BY HAND.
HOWEVER, IT MAY BE REMOVED BY HAND.
2. INSERT THE PHOTOCONTROL INTO THE RECEPTACLE.
2. INSERT THE PHOTOCONTROL INTO THE RECEPTACLE.
3. REATTACH THE CUPOLA CAP. IT SHOULD REATTACH WITH A
3. REATTACH THE CUPOLA CAP. IT SHOULD REATTACH WITH A
VERY AUDIBLE SNAP.
VERY AUDIBLE SNAP.
4. TURN THE PHOTOCONTROL WINDOW TOWARD NORTH BY
4. TURN THE PHOTOCONTROL WINDOW TOWARD NORTH BY
GRABBING THE CUPOLA BASE WITH BOTH HANDS, LIFTING AND
GRABBING THE CUPOLA BASE WITH BOTH HANDS, LIFTING AND
TURNING SIMULTANEOUSLY UNTIL THE CUPOLA WINDOW IS
TURNING SIMULTANEOUSLY UNTIL THE CUPOLA WINDOW IS
FACING NORTH. THE CUPOLA BASE AND THE PHOTOCONTROL
FACING NORTH. THE CUPOLA BASE AND THE PHOTOCONTROL
RECEPTACLE ARE KEYED SO THE PHOTOCONTROL TURNS AS
RECEPTACLE ARE KEYED SO THE PHOTOCONTROL TURNS AS
THE CUPOLA DOES.
THE CUPOLA DOES.
NOTE: FOR ELECTRICAL SAFETY PURPOSES, THE CUPOLA IS
NOTE: FOR ELECTRICAL SAFETY PURPOSES, THE CUPOLA IS
DESIGNED SO THAT IT WILL NOT TURN BEYOND 360 DEGREES.
DESIGNED SO THAT IT WILL NOT TURN BEYOND 360 DEGREES.
DEPENDING ON THE INITIAL ORIENTATION, IT MAY BE NECESS-
DEPENDING ON THE INITIAL ORIENTATION, IT MAY BE NECESS-
ARY TO TURN THE CUPOLA IN THE OTHER DIRECTION IF IT
ARY TO TURN THE CUPOLA IN THE OTHER DIRECTION IF IT
STOPS AND REFUSES TO TURN.
STOPS AND REFUSES TO TURN.
LL ADDER REST INSTALLATION:
ADDER REST INSTALLATION:
NOTE: IT IS DESIGNED TO BREAK-AWAY UNDER SIDE FORCE.
NOTE: IT IS DESIGNED TO BREAK-AWAY UNDER SIDE FORCE.
HOWEVER, IT CAN BE REATTACHED WITH A 1/4-20X3/4 BOLT
HOWEVER, IT CAN BE REATTACHED WITH A 1/4-20X3/4 BOLT
AND NUT AVAILABLE IN THE LADDER REST REPLACEMENT KIT
AND NUT AVAILABLE IN THE LADDER REST REPLACEMENT KIT
(THE KIT ALSO CONTAINS TWO ADDITIONAL LADDER RESTS.)
(THE KIT ALSO CONTAINS TWO ADDITIONAL LADDER RESTS.)
NOTE: THE LADDER REST IS A PRESS FIT DESIGN INTENDED
NOTE: THE LADDER REST IS A PRESS FIT DESIGN INTENDED
FOR INSTALLATION AFTER THE UNIT IS INSTALLED ONTO THE
FOR INSTALLATION AFTER THE UNIT IS INSTALLED ONTO THE
POST TOP.
POST TOP.
1. INSERT THE PIN FEATURE ON THE LADDER REST (SEE FIGURE 3)
1. INSERT THE PIN FEATURE ON THE LADDER REST (SEE FIGURE 3)
INTO THE LADDER REST HOLE LOCATED ON THE LEFT AND
INTO THE LADDER REST HOLE LOCATED ON THE LEFT AND
RIGHT SIDE OF THE LOWER HOUSING JUST ABOVE THE MOUNT
RIGHT SIDE OF THE LOWER HOUSING JUST ABOVE THE MOUNT
SET SCREWS.
SET SCREWS.
2. USING A RUBBER MALLET OR HAMMER, GENTLY KNOCK THE
2. USING A RUBBER MALLET OR HAMMER, GENTLY KNOCK THE
LADDER REST INTO THE HOLE. BE SURE TO KEEP THE LADDER
LADDER REST INTO THE HOLE. BE SURE TO KEEP THE LADDER
REST LINED UP WITH THE HOLE SO THAT THERE IS NO
REST LINED UP WITH THE HOLE SO THAT THERE IS NO
DAMAGE TO THE PIN.
DAMAGE TO THE PIN.
NOTES: IF THE PIN IS DAMAGED BEYOND REPAIR, REMOVE
NOTES: IF THE PIN IS DAMAGED BEYOND REPAIR, REMOVE
IT WITH PLIERS AND REATTACH USING A 1/4-20X3/4 BOLT
IT WITH PLIERS AND REATTACH USING A 1/4-20X3/4 BOLT
AND NUT.
AND NUT.
CAUTION
DO NOT TIGHTEN SET SCREWS
BEYOND 15 ft-lb. TORQUE.
!
CAUTION
THE LADDER REST IS FOR COSMETIC
PURPOSES ONLY. IT IS NOT
INTENDED FOR USE AS AN ACTUAL
REST FOR A LADDER.
!
PHOTOCONTROL:
PHOTOCONTROL:
NOTE: NO TOOLING IS NECESSARY FOR THE PHOTO-
NOTE: NO TOOLING IS NECESSARY FOR THE PHOTO-
CONTROL INSTALLATION OR ADJUSTMENT.
CONTROL INSTALLATION OR ADJUSTMENT.
- IF NO PHOTOCONTROL OPTION WAS SELECTED, A
- IF NO PHOTOCONTROL OPTION WAS SELECTED, A
CUSTOMER SUPPLIED PHOTOCONTROL WILL NEED TO
CUSTOMER SUPPLIED PHOTOCONTROL WILL NEED TO
BE INSTALLED. SEE STEP 1 BELOW.
BE INSTALLED. SEE STEP 1 BELOW.
- IF “PC” WAS SPECIFIED WHEN ORDERING, THE UNIT
- IF “PC” WAS SPECIFIED WHEN ORDERING, THE UNIT
WILL COME WITH THE PHOTOCONTROL INSTALLED. SEE
WILL COME WITH THE PHOTOCONTROL INSTALLED. SEE
STEP 4 BELOW.
STEP 4 BELOW.
- IF “NR” WAS SPECIFIED, THE UNIT COMES STANDARD
- IF “NR” WAS SPECIFIED, THE UNIT COMES STANDARD
WITH A SHORTING CAP AND THE STEPS BELOW ARE
WITH A SHORTING CAP AND THE STEPS BELOW ARE
NOT NECESSARY.
NOT NECESSARY.
FIGURE 3
FIGURE 3
LADDER REST INSTALLATION
LADDER REST INSTALLATION
PIN
PIN
GENTLY KNOCK HERE
GENTLY KNOCK HERE
FOR INSTALLATION.
FOR INSTALLATION.
IF LAMP IS MARKED
IF LAMP IS MARKED
IT CONTAINS MERCURY.
IT CONTAINS MERCURY.
FOLLOW DISPOSAL LAWS.
FOLLOW DISPOSAL LAWS.
SEE WWW.LAMPRECYCLE.ORG
SEE WWW.LAMPRECYCLE.ORG
Hg