9CH Mobile
SVR
Manual
44
1.7-2 PTZ transport
Select from ONVIF, HTML transport.
1.7-3 Preset setup
All features of PTZ can be configured from the live menu. You can also enter preset positions
through the preset set up option in the PTZ menu
Setting preset
Enter the preset setup then select your desired preset point from the dropdown bar
Enter dwell
Define the dwell time of a preset using the dropdown menu to select desired time. Dwell
number ranges from 0 to 255 seconds (the shortest to the longest).
Speed
Define the speed of the previous preset to the next preset, using the dropdown menu to select
desired time. The speed number ranges from 1 to 8 (the slowest to the fastest). The speed
might vary based on different PTZ camera’s settings.
Position
Use the joystick/controller to adjust the preset PTZ to your desired location.
Iris and auto iris
Adjust these settings as required
Focus and auto focus
Adjust these settings as required
Save presets
Once the above parameters are entered, the preset can be saved.
Clear all presets
To clear all the preset points of a PTZ camera, select ‘Clear All Presets’ and press Enter key on
the front panel or remote control.
Direct keyboard access
Direct keyboard Access mode allows RS-485 protocol to be directly transmitted to the RS-485
PTZ device
The
SVR
no longer handles the conversion of the RS-485 protocol
This enables the user to access the PTZ menus using the connected keyboard