3. SYSTEM INSTALLATION
•
Installing Removable Hard Drive
Push the HDD Holder into the socket as shown in the picture.
•
Installing SIM Card
Put your SIM Card into the holder
and
Take the SIM card holder and Insert it
into the socket as shown in the picture.
4. POWER IGNITION CONTROLS
•
Ignition On/Off status detectable by SW
•
If the ignition is off and the system is still on after 5 minutes, PowerBrick5.0
CV-i7 will shut down automatically.
•
If the ignition is turned on again and the power-off delay is in progress,
PowerBrick5.0 CV-i7 will cancel the delay function and will continue to operate
normally.
•
If the ignition is turned on again and the power-off delay ended, PowerBrick5.0
CV-i7 will shut down completely will power-on again automatically.
5.
POWER INPUT CONNECTOR
Power Brick5.0 CV'-i7's Power Wiring Diagram
6. DIAGNOSIS AND MAINTENANCE
4
1 GND 2 DC+ iN 3 IGNITION
POWER
HDD UPS
ACC WWAN
10A
Computer connector :
pin1-Ground
pin2-DC+ 9~32V
pin3-Ignition
For surepower, connect pin2 and pin3
togather
5