background image

Troubleshooting 

Problem 

Possible Solution 

No outdoor sensor 

reception 

If the wireless signal indicator shows no bars:

 

• Relocate the display and/or the outdoor sensor. 

The units must be within 330 ft (100 m) of each other.

 

• Make sure both units are placed at least . 3 feet(9 m) 

away from electronics that may interfere with the wireless

 

communication (such as TVs, microwaves, computers, etc.).

 

no bars 

• Use standard alkaline batteries (or lithium batteries in 

sensor when temperature is below -4ºF/-20ºC). Do not 

use heavy-duty or rechargeable batteries. NOTE: It may 

take a few minutes for display and sensor to synchronize 

after batteries are replaced. 

Outdoor 

temperature 

is flashing or

 

showing dashes 

Flashing of the outdoor temperature is generally an 

indication of wireless interference. 

1. Bring both the sensor and display indoors and remove 

batteries from each. 

2. Make sure the A-B-C switches on both units match.

 

3. Reinstall batteries in the outdoor sensor. 

4. Reinstall batteries in the display.

 

5. Let the units sit within a couple feet of each other 

for a few minutes to gain a strong connection. 

Inaccurate forecast 

• Weather Forecast icon predicts conditions for the next  

12 to 24 hours, not current conditions. 

• Has the learning mode icon disappeared from the 

display? Learning Mode must complete before forecast 

and pressure will be accurate.

 

• Allow unit to run continuously for 33 days. Battery

 

removal or resetting the display will restart Learning

 

Mode. After 14 days, forecast should be fairly accurate,

 

however, Learning Mode calibrates for a total of 33 days.

 

Inaccurate 

temperature  

or humidity 

• 

Make sure both the display and sensor are placed out of 

direct sunlight and away from any heat sources or vents 

(see page 9). 

• Make sure both units are positioned away from moisture 

sources (see page 9). 

Display screen 

not working 

• Check that the power adapter is plugged into the display 

and an electrical outlet.

 

• Reset the display by pressing the reset button, located 

on the back of the display. Date and time will need to be 

entered after a reset 

If your AcuRite product does not operate properly after trying the troubleshooting steps, 

visit www.AcuRite.com or email info@chaney-inst.com for assistance. 

12 

Summary of Contents for 01201

Page 1: ...y Setup 7 Set the Time Date and Units 8 Backlight Settings 8 Placement Guidelines 9 Using the Weather Station 10 Programmable Alarms 11 Troubleshooting 12 Care and Maintenance 13 Calibration 13 14 FCC...

Page 2: ...tents 1 Display 2 Outdoor Sensor 3 Power Adapter 4 Instruction Manual PRODUCT MUST BE REGISTERED IMPORTANT TO RECEIVE WARRANTY SERVICE PRODUCT REGISTRATION Register online to receive 1 year of warrant...

Page 3: ...mounting 2 Fold out Tabletop Stand 3 Power Adapter 4 Plug in for Power Adapter 5 RESET Button For full reset to factory defaults 6 A B C Switch ID code that must match sensor s A B C switch to ensure...

Page 4: ...I UD FF Ei JJ 3 33 Features and Benefits 1 2 3 4 5 6 18 17 16 15 14 13 12 11 7 8 9 8 10 4...

Page 5: ...r setup preferences and viewing indoor high low records 9 Button For setup preferences 10 Button For momentary backlight and dimmer settings 11 AUTO Icon Indicates display is in auto dimming brightnes...

Page 6: ...high quality alkaline batteries in the outdoor sensor for the best product performance Heavy duty or rechargeable batteries are not recommended 1 Slide off the battery compartment cover Take note of...

Page 7: ...roperly Only batteries of the same or equivalent type as recommended are to be used DO NOT incinerate used batteries DO NOT dispose of batteries in fire as batteries may explode or leak DO NOT mix old...

Page 8: ...You will automatically exit SET MODE if no buttons are pressed for 10 seconds Enter setup mode at any time by pressing the button Display Backlight Settings This weather station s colour display featu...

Page 9: ...ke a well covered tree branch The best location is 4 to 8 feet 1 to 2 metres above the ground with permanent shade and plenty of fresh air to circulate around the sensor Important Placement Guidelines...

Page 10: ...rometric pressure greatly affect the weather This weather station displays the current pressure with an arrow icon to indicate the direction the pressure is trending FALLING STEADY or RISING High and...

Page 11: ...LOW alarm value will be shown 5 Press and release the or buttons to adjust the alarm s LOW value 6 Press and release the button to end alarm adjustments OR press and release the button to cycle to the...

Page 12: ...the units sit within a couple feet of each other for a few minutes to gain a strong connection Inaccurate forecast Weather Forecast icon predicts conditions for the next 12 to 24 hours not current con...

Page 13: ...m press and release the or buttons to calibrate the data value higher or lower from the actual reading 3 To save your adjustments press and release the button to adjust the next preference The icon wi...

Page 14: ...ial installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communic...

Page 15: ...SOLE WARRANTY FOR THE PRODUCTS AND IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED ALL OTHER WARRANTIES OTHER THAN THE EXPRESS WARRANTY SET FORTH HEREIN ARE HEREBY EXPRESSLY DISCLAIMED...

Page 16: ...f precision instruments designed to provide you with information you can depend on to Plan your day with confidence Chaney Instrument Co All rights reserved AcuRite is a registered trademark of the Pr...

Reviews: