3. Press the 

” or “

 buttons to calibrate the data value higher or lower from the 

actual reading.

 

4. Press the 

“SET”

 button to confirm the calibration 

adjustment. Note: The “   ” icon remains illuminated next 

to calibrated values.

 

Calibrate the Rain Gauge 

The rain gauge on the 5-in-1 sensor can be calibrated to improve accuracy.

 

Items Needed

: 5-in-1 sensor, display unit, plastic cup, pin, screw driver

 

1.  First, ensure 5-in-1 sensor is perfectly level using built-in bubble level.

 

2.  Place display unit close so you can monitor it during calibration.

 

3.  Make a pin hole in the bottom of a plastic cup. Hold the cup over the rain gauge 

and fill it with exactly 1 cup (8oz) of water, allowing the water to drip into the rain 

gauge. You should hear the internal buckets tip and see water drain through the rain 

gauge. 

4.  A few seconds after each bucket tip, the display unit displays rainfall in 

approximately 0.01” (.254 mm) or more increments.

 

5.  The cup of water should take more than 20 minutes to empty; a quicker period will 

result in inaccurate calibration. Try to simulate a normal steady rainfall. When cup is 

empty of water, display unit should register 1.06” (26.924 mm)

 

Tips 

• There should be nearly an equal number of water drops (about 25 water drops) 

between bucket tips. If not, adjust the calibration screws on the bottom of the 5-in-1 

sensor until an equal number of water drops are tipping the buckets. Then, restart the 

calibration procedure.

 

• If you don’t hear the buckets tipping and see water dripping alternately out of 

each drain, there may be an issue with the rain gauge or it’s adjustment. See 

Troubleshooting on page 19.

 

Adjustment 

If the rain gauge doesn’t register close to 1.06” (26.924 mm), make an EQUAL 

adjustment to the two calibration screws on the bottom of the 5-in-1 sensor. Turning 

screws clockwise increases rainfall; counter clockwise decreases rainfall.

 

• To adjust the rainfall reading by 2% turn both screws 1/8  of a turn.

 

• To adjust the rainfall reading by 4% turn both screws 1/4 of a turn.

 

• To adjust the rainfall reading by 8% turn both screws 1/2 of a turn.

 

Watch the video at www.acurite.com/5n1

 

Summary of Contents for 01500

Page 1: ...sor Setup 7 Display Unit Setup 8 Set the Time Date 9 Measurement Units 10 Placement Guidelines 11 5 in 1 Sensor Installation 12 Using the Weather Center 13 Weather Ticker 14 Programmable Alarms 16 Tro...

Page 2: ...to the LCD screen prior to using this product Locate the tab and peel off to remove Package Contents 1 Display unit with tabletop stand 2 5 in 1 sensor 3 Sensor mounting bracket 4 Mounting hardware 5...

Page 3: ...olar radiation heating resulting in more accurate temperature measurement 3 A B C Switch ID code that must match display s A B C switch to ensure units synchronize 4 Battery Compartment 7 9 5 Temperat...

Page 4: ...4 Features Benefits Display Unit 37 20 2 1 5 19 21 22 23 24 25 26 27 28 29 30 31 32 33 34 7 9 10 11 12 38 39 35 12 16 15 14 14 17 13 18 6 4 3 36 8...

Page 5: ...6 Button For manually cycling Weather Ticker messages 17 HISTORY MODE Button Press for all time low and date recorded for current category selected on display 31 Press twice for all time high and date...

Page 6: ...ID code that must match 5 in 1 sensor s A B C switch to ensure units synchronize 4 CLEAR TODAY Button Clears data recorded since 12 00am 7 8 5 CLEAR ALL Button Clears all recorded data without having...

Page 7: ...n 1 sensor requires lithium batteries in low temperature conditions Cold temperatures can 3 cause alkaline batteries to function improperly Use lithium batteries in the 5 in 1 sensor for temperatures...

Page 8: ...N ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS BATTERY SAFETY Clean the battery contacts and also those of the device prior to battery installation Remove batteries from equipment which is not to b...

Page 9: ...ndicators 4 Press the SET button to confirm hour selection 5 Press the or buttons to adjust minutes 6 Press the SET button to confirm minute selection The clock is now set Set the Date 1 Press the or...

Page 10: ...ayed on the Selectable Category part of the display unit 2 Press the SET button to set the unit preference 3 Press the or buttons to select STAND for standard or METRIC for metric units 4 Press the SE...

Page 11: ...way from large metallic items thick walls metal surfaces or other objects that may limit wireless communication PREVENT WIRELESS INTERFERENCE Place both units at least 3 feet 9 m away from electronic...

Page 12: ...nger screws included in the hardware bag 2 Insert the mounting base into the hole on the bottom of the sensor 3 Make sure the arrows on the top of the sensor are pointed in the proper direction and th...

Page 13: ...cons at www AcuRite com acurite icons MOSTLY CLOUDY SNOW LIKELY RAIN SNOW MIX LIKELY CLOUDY PARTLY CLOUDY RAIN LIKELY flashing stormy flashing stormy Weather Select The Weather Select area on the disp...

Page 14: ...eek OUTDOOR TEMP THIS WEEK LOW Lowest temperature recorded this calendar week OUTDOOR TEMP THIS MONTH HIGH Highest temperature recorded this calendar month OUTDOOR TEMP THIS MONTH LOW Lowest temperatu...

Page 15: ...the message is now active in the ticker appears on screen cycle PRESS the remove button to deactivate the current scrolling message The corresponding remove appears on screen to the left of the messa...

Page 16: ...ecorded Similarly the storm alarm sounds when a large atmospheric pressure drop occurs which usually indicates an oncoming storm Note The storm alarm is NOT intended to be a safety device or warning s...

Page 17: ...eactivate on alarm ALARM Press and hold to set or adjust on alarm value Silence a Sounding Alarm The alarm sounds initially for a few minutes then silences itself The alarm then sounds every few minut...

Page 18: ...ts sit within a couple feet of each other for about 20 minutes to gain a strong connection Outdoor temperature is flashing or showing dashes Flashing of the outdoor temperature may be an indication of...

Page 19: ...ate wind readings What is wind reading being compared to Pro weather stations are typically mounted at 30 ft high or more Make sure to compare data using a sensor positioned at the same mounting heigh...

Page 20: ...llector Cup Remove and empty rain collector debris filter The debris filter is located in the rain col lector funnel Remove from the top by gently squeezing and pulling out Clean the Wind Vane Anemome...

Page 21: ...take more than 20 minutes to empty a quicker period will result in inaccurate calibration Try to simulate a normal steady rainfall When cup is empty of water display unit should register 1 06 26 924...

Page 22: ...e in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to...

Page 23: ...laced by Chaney Transportation costs and charges for returned goods shall be paid for by the purchaser Chaney hereby disclaims all responsibility for such transportation costs and charges This warrant...

Page 24: ...to provide you with information you can depend on to Plan your day with confidence www AcuRite com Chaney Instrument Co All rights reserved AcuRite is a registered trademark of the Chaney Instrument C...

Reviews: