background image

Adjust the Wind Vane Orientation (Optional)

Note: 

Most users will not need to complete this step.

When mounting the AcuRite Atlas outdoor device, as 

long as the rear solar panel is facing south, the wind 

the factory. However, if you must mount the outdoor 

device in a different direction or otherwise need to adjust 

its wind vane orientation, complete the steps below.

1.  

In the battery 

compartment of the 

outdoor device, locate 

and press the calibration 

button. The red LED 

2.  

Point the wind vane to  

north. You may need a  

 

north orientation.

3.  

While holding the vane  

facing north, press the  

calibration button in the  

battery compartment again.  

 

rapidly. Wind direction  

information will now use 

the new orientation.

NORTH

TEMPERATURE RANGE

HUMIDITY RANGE

WIND SPEED

WIND DIRECTION

RAIN

UV INDEX

LIGHT INTENSITY

*LIGHTNING

-40 to 158

°

F (-40 to 70

°

C)

30 seconds

30 seconds

10 seconds

30 seconds

30 seconds

30 seconds

30 seconds

10 seconds

1-100% RH

0-160 mph (0-257 km/h)

360

°

.01 inch intervals (mm) 

0 to 15 index

to 120,000 Lumens

Up to 25 miles away (40 km)

Operating  

Range

Reading 

Frequency

Accuracy

+_

1

°

F

+_

3

°

+_

2%RH

+_

5%

+_

1

n/a

n/a

+_

1mph  10 mph 

<_

+_

10%  10 mph 

>

6

7

HAVING PROBLEMS?

We’re Here to Help.

Get more information or download the full 

AcuRite Atlas™ product manual.

Visit us online

www.AcuRite.com

Limited One (1) Year Warranty

A

We warrant that the AcuRite Atlas Environmental Monitoring station premium product we manufacture and cover under this 

warranty is of good material and workmanship and, when properly installed and operated, will be free of defects for a period 

of one (1) year from the date of purchase.
The AcuRite Atlas Environmental Monitoring station which, under normal use and service, is proven to breach the warranty 

contained herein within ONE (1) YEAR from date of sale will, upon examination by us, and at our sole option, be repaired 

or replaced by us. Transportation costs and charges for returned goods shall be paid for by the purchaser. We hereby 

disclaim all responsibility for such transportation costs and charges. This warranty does not cover normal wear and tear not 

affecting the functionality of the product, or products that have been damaged (including by acts of nature), tampered with, 

abused, improperly installed, or repaired or altered by anyone other than our authorized representatives. Remedy for breach 

of this warranty is limited to repair or replacement of the defective item(s). If we determine that repair or replacement is not 

feasible, we may, at our option, refund the amount of the original purchase price (excluding shipping). 
THE ABOVE-DESCRIBED WARRANTY IS THE SOLE WARRANTY FOR THE ACURITE ATLAS ENVIRONMENTAL MONITORING 

STATION PREMIUM PRODUCT AND IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. ALL 

WARRANTIES OTHER THAN THE EXPRESS WARRANTY SET FORTH HEREIN ARE HEREBY EXPRESSLY DISCLAIMED TO 

THE EXTENT PERMITTED BY LAW.
We expressly disclaim all liability for special, consequential, or incidental damages, whether arising in tort or by contract 

from any breach of this warranty. Some states do not allow the exclusion or limitation of incidental or consequential 

damages, so the above limitation or exclusion may not apply to you. We further disclaim liability from personal injury 

relating to its products to the extent permitted by law. By acceptance of any of our products, the purchaser assumes all 

any other obligation or liability in connection with the sale of our pr

is authorized to modify or waive the terms of this warranty unless done in writing and signed by a duly authorized agent 

of ours. In no case shall our liability for any claim relating to our products, your purchase or your use thereof, exceed the 

original purchase price paid for the product.
WARRANTY CLAIMS 
T
1. Contact AcuRite Support at support@chaney-inst.com and provide opportunity for Customer Support to resolve any issue
2. In the event that an issue cannot be resolved over the phone, customer shall send the product(s) in for evaluation to AcuRite 

at the contact address (see below)
3. Chaney Instrument Service department will repair or replace product as necessary after evaluation
The terms of this Limited Warranty shall be governed in all respects by and construed in accordance with the laws of the State 

out of this Limited Warranty or your use of the product shall be in the state court located in Walworth County, Wisconsin. You 

agree to submit to the jurisdiction of such court.
Contact Information 

If you have questions about this Limited Warranty, please contact us at: 
AcuRite 

Attn: Warranty Inquiry 

965 Wells St, Lake Geneva, WI 53147 

warranty@chaney-inst.com

FCC Statement

This device complies with part 15 of the FCC rules. Operation is subject to the 

following two conditions:

1- This device may NOT cause harmful interference, and

2- This device must accept any interference received, including interference 

that may cause undesired operation.

NOTE: This equipment has been tested and found to comply with the limits 

for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits 

are designed to provide reasonable protection against harmful interference 

in a residential installation. This equipment generates, uses and can radiate 

radio frequency energy and, if not installed and used in accordance with 

the instructions, may cause harmful interference to radio communications. 

However, there is no guarantee that interference will not occur in a particular 

installation. If this equipment does cause harmful interference to radio or 

television reception, which can be determined by turning the equipment off 

and on, the user is encouraged to try to correct the interference by one or 

more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and the receiver.

• Connect the equipment into an outlet on a circuit different from that to 

 

   which the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.

NOTE: The manufacturer is not responsible for any radio or TV interference 

caused by unauthorized modifications to this equipment. Such modifications 

could void the user authority to operate the equipment.
©Chaney Instrument Co. All rights reserved.  AcuRite is a registered 

trademark of the Chaney Instrument Co., Lake Geneva, WI 53147. All other 

trademarks and copyrights are the property of their respective owners. 

AcuRite uses patented technology. 
Visit www.AcuRite.com/patents for details.

Summary of Contents for Atlas 06061

Page 1: ...AcuRite Atlas Indoor Display model 06061 Instruction Manual...

Page 2: ...ontains sensors that read temperature humidity wind speed and direction rainfall UV light intensity and optionally lightning requires optional Lightning Detection Sensor may be purchased separately Th...

Page 3: ...N 3 Install Batteries In the battery compartment of the AcuRite AtlasTM outdoor device install four AA alkaline or lithium batteries Lithium batteries are recommended in low temperature conditions esp...

Page 4: ...n screen prompts to set the time date and units of measurement Mount Outdoor Device Set Up Display 1 Find a suitable place to mount the outdoor device At least 5 feet 1 5 meters off the ground Rear so...

Page 5: ...door display select the Menu icon 3 Select Sensors Note If you re replacing an outdoor device select Remove A Sensor and remove the batteries and power from the outdoor device that is being replaced 4...

Page 6: ...ainfall for current week and month and year to date Display settings volume brightness sleep mode Indoor temperature humidity Current date time Menu Select to view monthly records configure alarms or...

Page 7: ...n Backlight set the backlight auto dim and sleep mode settings You can set the indoor display s time and date settings including the time zone Daylight Saving Time and the time and date format How To...

Page 8: ...ading Records Shows high low and accumulation reading records by month You can delete the current day s readings this feature is commonly accessed when inaccurate readings occur during the setup proce...

Page 9: ...4 Using the left and right arrows select an alarm type select Next 5 Set the condition that activates the alarm When the condition is reached 6 Verify the alarm icon is set to ON 7 Select Save and Ex...

Page 10: ...e left and right arrows select the reading type of the alarm to be disabled select Next 5 Select the alarm icon until it displays OFF How To Disable All Alarms 1 Select Alarms 2 Select Indoor alarms o...

Page 11: ...ent to My AcuRite or Weather Underground READING CALIBRATIONS How To Set A Reading Calibration 1 From the top left section select the Menu icon 2 Select Calibrate 3 Select Indoor to adjust readings ta...

Page 12: ...oduct WARRANTY CLAIMS T 1 Contact AcuRite Support at support chaney inst com and provide opportunity for Customer Support to resolve any issue 2 In the event that an issue cannot be resolved over the...

Page 13: ...AcuRite Atlas Outdoor Device model 06059 Instruction Manual...

Page 14: ...ns at its installation location The outdoor device contains sensors that read temperature humidity wind speed and direction rainfall UV light intensity and optionally lightning requires optional Light...

Page 15: ...le level 6 UV and light sensor 7 Rainfall collector 8 Wind direction vane 1 2 3 4 5 7 6 8 Open the battery compartment and insert four 4 AA alkaline or lithium batteries Lithium batteries are recommen...

Page 16: ...later Visit www Acurite com for more information Outdoor Device Placement AcuRite Atlas is designed to remain outdoors all year long Mount the outdoor device in a location that meets all the requirem...

Page 17: ...pas or other bodies of water Maximize Wind Accuracy It s recommended to mount the outdoor device at least 5 feet 1 5 meters off the ground higher is better for wind measurement The National Weather Se...

Page 18: ...2 Point the wind vane to north You may need a north orientation 3 While holding the vane facing north press the calibration button in the battery compartment again rapidly Wind direction information...

Page 19: ...ice paid for the product WARRANTY CLAIMS T 1 Contact AcuRite Support at support chaney inst com and provide opportunity for Customer Support to resolve any issue 2 In the event that an issue cannot be...

Page 20: ...gistered trademark of the Chaney Instrument Co Lake Geneva WI 53147 All other trademarks and copyrights are the property of their respective owners AcuRite uses patented technology Visit www AcuRite c...

Reviews: