background image

Copyright Chaney Instrument Co.   

 

Set Up Your Indoor Display

1

Plug in the power adapter. Once the display is 

powered on, it will help guide you through the 

next steps.

Plug In

POWER

ON

3

Install Batteries

In the battery compartment of the AcuRite

®

 Atlas

TM

 

outdoor device, install four AA alkaline or lithium 

batteries. Lithium 

batteries are 

recommended in 

low temperature 

conditions, especially 

below -4

o

F / -20

o

C.

Note: Heavy duty or 

rechargeable batteries 

are not recommended.

2

Lift Antenna

On the top of the 

display, lift the 

antenna for optimal 

signal reception.

Package Contents

  AcuRite

®

 Atlas

TM

 Indoor HD Display

  AC Power Adapter for Display
    Wall Mounting Bracket (optional)

AcuRite

®

 Atlas™ is an 

environmental monitoring station 

that delivers key information on 

current outdoor conditions in 

your exact location.  The outdoor 

device contains sensors that 

read temperature, humidity, wind 

speed and direction, rainfall, UV, 

light intensity, and optionally 

lightning (requires optional 

Lightning Detection Sensor; 

may be purchased separately). 

These readings are transmitted 

over a 433 MHz wireless radio 

frequency (RF) to be received by 

the AcuRite Atlas indoor touch 

screen display.

NOTE: To view your outdoor 

readings online from My AcuRite  

an AcuRite

®

 Access™ is required; 

may be purchased separately.

How It Works

2

3

Summary of Contents for Atlas 06061

Page 1: ...AcuRite Atlas Indoor Display model 06061 Instruction Manual...

Page 2: ...ontains sensors that read temperature humidity wind speed and direction rainfall UV light intensity and optionally lightning requires optional Lightning Detection Sensor may be purchased separately Th...

Page 3: ...N 3 Install Batteries In the battery compartment of the AcuRite AtlasTM outdoor device install four AA alkaline or lithium batteries Lithium batteries are recommended in low temperature conditions esp...

Page 4: ...n screen prompts to set the time date and units of measurement Mount Outdoor Device Set Up Display 1 Find a suitable place to mount the outdoor device At least 5 feet 1 5 meters off the ground Rear so...

Page 5: ...door display select the Menu icon 3 Select Sensors Note If you re replacing an outdoor device select Remove A Sensor and remove the batteries and power from the outdoor device that is being replaced 4...

Page 6: ...ainfall for current week and month and year to date Display settings volume brightness sleep mode Indoor temperature humidity Current date time Menu Select to view monthly records configure alarms or...

Page 7: ...n Backlight set the backlight auto dim and sleep mode settings You can set the indoor display s time and date settings including the time zone Daylight Saving Time and the time and date format How To...

Page 8: ...ading Records Shows high low and accumulation reading records by month You can delete the current day s readings this feature is commonly accessed when inaccurate readings occur during the setup proce...

Page 9: ...4 Using the left and right arrows select an alarm type select Next 5 Set the condition that activates the alarm When the condition is reached 6 Verify the alarm icon is set to ON 7 Select Save and Ex...

Page 10: ...e left and right arrows select the reading type of the alarm to be disabled select Next 5 Select the alarm icon until it displays OFF How To Disable All Alarms 1 Select Alarms 2 Select Indoor alarms o...

Page 11: ...ent to My AcuRite or Weather Underground READING CALIBRATIONS How To Set A Reading Calibration 1 From the top left section select the Menu icon 2 Select Calibrate 3 Select Indoor to adjust readings ta...

Page 12: ...oduct WARRANTY CLAIMS T 1 Contact AcuRite Support at support chaney inst com and provide opportunity for Customer Support to resolve any issue 2 In the event that an issue cannot be resolved over the...

Page 13: ...AcuRite Atlas Outdoor Device model 06059 Instruction Manual...

Page 14: ...ns at its installation location The outdoor device contains sensors that read temperature humidity wind speed and direction rainfall UV light intensity and optionally lightning requires optional Light...

Page 15: ...le level 6 UV and light sensor 7 Rainfall collector 8 Wind direction vane 1 2 3 4 5 7 6 8 Open the battery compartment and insert four 4 AA alkaline or lithium batteries Lithium batteries are recommen...

Page 16: ...later Visit www Acurite com for more information Outdoor Device Placement AcuRite Atlas is designed to remain outdoors all year long Mount the outdoor device in a location that meets all the requirem...

Page 17: ...pas or other bodies of water Maximize Wind Accuracy It s recommended to mount the outdoor device at least 5 feet 1 5 meters off the ground higher is better for wind measurement The National Weather Se...

Page 18: ...2 Point the wind vane to north You may need a north orientation 3 While holding the vane facing north press the calibration button in the battery compartment again rapidly Wind direction information...

Page 19: ...ice paid for the product WARRANTY CLAIMS T 1 Contact AcuRite Support at support chaney inst com and provide opportunity for Customer Support to resolve any issue 2 In the event that an issue cannot be...

Page 20: ...gistered trademark of the Chaney Instrument Co Lake Geneva WI 53147 All other trademarks and copyrights are the property of their respective owners AcuRite uses patented technology Visit www AcuRite c...