INSTALLATION
INSTALLATION OF TWO HEATING CIRCUITS
CONTROLLED BY CONTROL UNIT AND
ZMC-1 MODULE
General diagram
This configuration controls two heating circuits (radiators
or floor heating). In addition, the Room unit features a
remote monitoring of the two circuits.
You can adjust those two circuits depending on the outside
temperature.
This is the ideal configuration for floor heating with additional
heating provided by radiators.
You can select various heating functions, and program up
to three weekly schedules, as well for the central heating as
for the hot water production.
AF120
Room Unit
MCBA
RAM
VF202
ZMC1
SQK
Optional accessories
Code
Description
10800034
Room Unit RSC :
Supplied with outside temperature sensor.
10800119
ZMC-1 module (kit) :
Controls the second heating circuit - alarm contact - operates only in conjonction
with the Room Unit RSC.
10800036
Clip-in interface RMCIEBV3 :
Enables communications between the MCBA and the Room Unit RSC.
10800045
Contact sensor 2k
Ω
— VF202 :
To be mounted on the outlet of controlled circuit.
10510900
Contact thermostat RAM 5109 :
Required to protect all fl oor heating circuits.
10510100
Outside temperature sensor 12k
Ω
— AF120
10800104
Collector 2 circuits DN32 :
Whith integrated wall brackets.
10800107
High temperature kit DN32:
Including: one circulation pump, two isolating valves,
check valve, two thermometers.
10800106
Low temperature kit DN32:
Including: one circulation pump, two isolating valves, check valve,
two thermometers, the 3-way valve with integrated bypass.
10800142
Connection kit DN32 to the manifold:
Including: two fl exible 1"1/2 hoses and 1"1/4 reduction fi ttings.
10800019
Servomotor SQK 349 :
Electromechanical servomotor included in low temperature kit.
(Opening / closing time: 150 sec.)