7.2
BOILER ROOM
•
Keep vents free at all times.
•
Do not store inflammable products in the boiler room.
•
Take care not to store corrosive products near the boiler, such
as paints, solvents, chlorine, salt, soap and other cleaning
products.
•
If you smell gas, do not switch on the light or light a flame. Turn
off the mains gas tap at the meter and inform the appropriate
services immediately.
7
USER GUIDE
7.1.5
GAS BURNER - RESETTING
If the atmospheric burner is not working:
1.
Remove the protective cover.
2.
Press the red button to start the burner.
If the burner is not working, isolate the electricity
supply before attempting to reset the safety thermostat.
3.
Remove the circular cover on the boiler top and press the red
safety thermostat button
.
Wait until the boiler temperature is below 60° C then
replace the casing front panel.
4. If the burner lights, replace the cover.
6. If the fault persists, notify the installing engineer.
Starting the burner.
In normal operation, the gas burner starts automatically whenever the
boiler temperature falls below the set temperature.
To ensure your system operates properly, have it
professionally serviced once a year before the central
heating season begins.
Fig. 22: Safety thermostat reset button
Fig. 21: Burner reset button
13