AD-net Technology., CO LTD
www.ad-net.com.tw
-
25-
SNMP management includes SNMP server option (stop/start/test), time setting
interval (10~60000 minutes), SNMP server IP address and SNMP server status
display (disable/enable, connect successfully/fail).
Note: It needs to get the current time again once the power is off.
5.7.2
Change the password
Fig 5.7-2 Change the password
The change will be valid after confirm the submitting.
5.7.4
Default parameter recovery
Default parameter recovery can make all the parameters recover to factory
default except the IP address of equipments and the devices will reboot automatically.
If not selected to remain current IP, IP address will also recover to factory default
(192.168.1.2). At the same time, due to the change of IP, it will show Access failed.
Then we need to restart Web Server.
Fig 5.7-3 default parameters recovery
AN-TDM-IP-1E1/2E1-A supports changing E1/T1 port number. For example,
change AN-TDM-IP-2E1/A E1/T1 port number to 1. It is shown as follows:
Step 1. Generate the configuration code by verification code. Input the MAC
address of AN-TDM-IP-2E1/A and set E1 number as 1 and then click Generate.
Manuel de l'usager du Mux IP vers 2xE1
www.hypercable.fr