To check the accuracy of line laser level
To check the accuracy of line laser level (slope of plane)

Set  up  the  instrument  between  two  walls,  the  distance  is  5 

m.Turn  on  the  Cross  Line  Laser  and  mark  the  point  of  cross 

laser line on the wall.

Set up the instrument 0,5-0,7m away from the wall and make, as 

described above, the same masrks. If the difference {a1-b2} and 

{b1-b2} is less then the value of “accuracy” (see spesifications), 

there is no need in calibration.

Example: when you check the accuracy of Cross Line Laser the 

difference is {a1-a2}=5 mm and {b1-b2}=7 mm. The 

instrument’s  error:  {b1-b2}-{a1-a2}=7-5=2  mm.  Now  you  can 

compare this error with standard error.

If  the  accuracy  of  Cross  Line  Laser  isn’t  corresponding  with  

claimed accuracy, contact the authorized service center. 

w w w . e k t

2

. c o m

Summary of Contents for CUBE MINI

Page 1: ...Operating manual Line laser level ADA CUBE MINI MEASUREMENT FOUNDATION INSTRUMENTS w w w e k t 2 c o m Electronics Katrangi Trading...

Page 2: ...lanes It is used for determination height making horizontal and vertical planes Specifications Leveling Range self leveling 3 Accuracy 2mm 10m Working Range 10 m depends on illumination of work area P...

Page 3: ...ttery compartment Put in 2xAAAlkaline batteries Take care to correct polarity Close battery compartment ATTENTION If you are not going to use instrument for a long time take out batteries Laser lines...

Page 4: ...CUBE MINI INSTRUMENTS Features 1 laser emitting window 2 battery cover 3 compensator switch 4 tripod mount 1 4 3 1 2 4 w w w e k t 2 c o m Electronics Katrangi Trading...

Page 5: ...n the instrument turn the compensator switch 3 to the position ON When enabled the vertical and horizontal plane projected constantly Visual alarm blinking line and audible signal indicate that the de...

Page 6: ...CUBE MINI INSTRUMENTS APPLICATION DEMONSTRATION w w w e k t 2 c o m Electronics Katrangi Trading...

Page 7: ...7m away from the wall and make as described above the same masrks If the difference a1 b2 and b1 b2 is less then the value of accuracy see spesifications there is no need in calibration Example when...

Page 8: ...ease note the distance of B to A should be 5m Measure the distance between M to cross laser lune if the difference is over 3mm the laser is out of calibration please contact with seller to calibrate t...

Page 9: ...Please handle measuring instrument with care Clean with soft cloth only after any use If necessary damp cloth with some water If instrument is wet clean and dry it carefully Pack it up only if it is...

Page 10: ...as or the other way round please wait some minutes before carrying out measurements Electromagnetic acceptability EMC It cannot be completely excluded that this instrument will disturb other instrumen...

Reviews: