background image

 

© Adam Equipment Company 2009 

 

 

 

Adam Equipment 

 

 
 
 
 

Grain Scale 

Model: CQT1751GR 

 

  
 

pn. 9757 rev B

 

 

 

 

 

Summary of Contents for CQT1751GR

Page 1: ... Adam Equipment Company 2009 Adam Equipment Grain Scale Model CQT1751GR pn 9757 rev B ...

Page 2: ... Adam Equipment Company 2009 ...

Page 3: ...OUR SCALE 8 3 5 STORING WHEN NOT IN USE 9 4 0 BASIC OPERATION 10 4 1 TURNING ON THE SCALE 10 4 2 ZEROING TARE 10 4 3 WEIGHING 10 4 4 WEIGHING UNITS 10 4 5 GRAIN DETERMINING 11 5 0 PARAMETERS 14 5 1 PARAMETER SETTING 14 5 2 AUTO POWER OFF 14 5 3 SETTING THE BACKLIGHT 15 6 0 CALIBRATION 16 7 0 TROUBLE SHOOTING 17 7 1 ERROR MESSAGES 17 7 2 REPLACEMENT PARTS AND ACCESSORIES 18 8 0 SPECIFICATIONS 20 9 ...

Page 4: ... Adam Equipment Company 2009 4 ...

Page 5: ...the Allen key supplied in the box It is advisable to keep the shipping protection screw and the round cover along with the packing box for using during shipping to another location in future Shipping protection screw Round cover around the screw 2 Place the pan which comes separately packed in the receptacles on the top cover Use the screw that you removed to screw the plastic pan into place Be ca...

Page 6: ...artment 3 3 OVERVIEW DISPLAY KEY BOARD BEHIND AC adapter socket Lock down slot TOP Stainless Steel pan Plastic Pan LCD display On Off key Turns the balance power on off S P CE key Stores weight readings and does percentage calculation as well as clearing stored values Recall Tare key Recalls stored weighings results and also to zeros and tares the balance ...

Page 7: ...t Company 2009 7 BOTTOM Battery compartment screws Battery compartment cover Batteries are not included DISPLAY ZERO indicator Indicates when the scale is at zero STABLE indicator Indicates when the reading is stable ...

Page 8: ...t leave the batteries inside the scale if you are using the scale with the AA batteries and are not using it on not using it for a long time Keep free from vibration Do not place near heavy or vibrating machinery Avoid high humidity that might cause condensation and keep away from direct contact with water Do not place near open windows air conditioning vents or fans that may cause a draught and u...

Page 9: ...9 9 3 5 STORING WHEN NOT IN USE If you have any of the HighlandTM series or CoreTM or Grain Scale product lines you can store them easily on top of each other To save space and protect them from damage Without Shield With Shield ...

Page 10: ...Recall Tare key to set a new zero point Zero will be set if the reading on the scale is less than 70g This may be necessary if the weight is not reading zero with no weight on the pan The zero indicator will show in the top left corner of the LCD If you are using a container to weigh then you can place this on the platform and press the Recall Tare key the display will show zero and NET on the dis...

Page 11: ...the net weight the first net weight of the grain in this example lets say the total weight was 400g Store Kg Hl 3 Press the S P CE key it calculates the relation between g and Kg Hl and saves the value The balance will show Store 1 for 2 seconds and then xx x Kg Hl In this example it will show 80 00 Kg Hl Store Kg Hl The Store symbol lights up when the first net weight is stored and the Kg Hl symb...

Page 12: ...Store 2 for 2 seconds and then xx x Kg Hl If the screenings were 30 0g then in this example it would show 6 00 Kg Hl Store Kg Hl The Store symbol lights up when the second net weight is stored and the Kg Hl symbol also lights up 8 To determine the percentage of screenings to the initial grain press the S P CE key again The balance will show Per on the display for approximately 2 seconds and then X...

Page 13: ...e screened grain if 2 stored weights are in the memory but it does not show percentage if you press the S P CE key it will calculate the percentage 10 After completing the test you must clear the memory This is done by pressing and holding down the S P CE key for 2 seconds until Clear is displayed on the scale and then release the S P CE key 11 If the balance is turned off during the weighing proc...

Page 14: ... e no weight movement or key presses 1 To set this parameter turn the power off press and hold the Recall Tare key then press the on off key once then release the Recall Tare key 2 After a few seconds the display will show the first function PWR 3 Press the S P CE key until you the display shows you XX PWR where XX is last setting 4 Press Recall Tare to select the settings as follows Off PWR Auto ...

Page 15: ... backlight to be on at all times OFF BL Sets the backlight to be off 1 To set this parameter turn the power off press and hold the Recall Tare key then press the On Off key once then release the Recall Tare key 2 After a few seconds the display will show the first function PWR 3 Press the S P CE key until you the display shows you XX BL where XX is last setting 4 Press Recall Tare to select the se...

Page 16: ...er turn the power off and press S P CE and Recall Tare keys together once during the self check sequence 2 The display will show UnLOAD remove any weight from the pan 3 Press the Recall Tare key to enter a zero value 4 The value last used for calibration will be displayed To select a different calibration weight press the S P CE key You can use either a 500g 1000g or 1500g calibration weight 5 Onc...

Page 17: ...amaged Electronics damaged Remove any weight form the stainless steel pan and try rebooting Try calibrating the machine Unit E Unit error Low battery indicator Batteries may be flat Change the batteries FAIL Calibration failure Incorrect mass used to calibrate The user calibration is not within 5 of factory calibration Possible damaged to loadcell Try to recalibrate check that the weight used to c...

Page 18: ...f the more common items follows Part Number Description 4178 AC adapter USA plug 12VAC 150mA 9541 AC adapter UK plug 12VAC 150mA 9542 AC adapter Euro plug 12VAC 150mA 9543 AC adapter SA plug 12VAC 150mA 5099 AC adapter Australian plug 12VAC 150mA 9502 120 mm Stainless steel pan 9511 Draft shield lid 9510 Draft shield without lid 9306 In use wet cover 8030 Security lock and cable ...

Page 19: ... Adam Equipment Company 2009 19 ...

Page 20: ...rature 0ºC to 40ºC 32ºF to 104ºF Power Supply 12VAC 150mA adapter or 6x AA batteries Calibration Push button calibration using external mass Calibration Mass 500g 1000g or 1500g user selectable Display 6 digit LCD 18mm digits with backlight Draft shield diameter x h 132mm ø x 82mm 5 2 ø x 3 2 Balance Housing ABS Plastic Pan Size 120mm ø 5 1 ø Overall Dimensions w x d x h 173 x 255 x 86mm 6 8 x 10 ...

Page 21: ...l packaging and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warranty does not cover equipment where defects or poor performance is due to misuse accidental damage exposure to radioactive or corrosive materials negligence faulty installation unauthorised modifications or attempted repair or failure to observe the requirements a...

Page 22: ... Adam Equipment Company 2009 22 ...

Page 23: ...in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded interconnect cables must be employed with this equipment to insure compliance with the pertinent RF emission limits governing this device Changes or modifications not expressly approved by Adam Equipment could void the user s authority to ope...

Page 24: ...ission of Adam Equipment Adam Equipment reserves the right to make changes to the technology features specifications and design of the equipment without notice All information contained within this publication is to the best of our knowledge timely complete and accurate when issued However we are not responsible for misinterpretations which may result from the reading of this material The latest v...

Reviews: