background image

(P.N. 3136611513 - Revision A, Apr 2014)

 

 

 

© Adam Equipment Company 2014

 

 

 

Adam Equipment 

 
 
 
 

 

 

 

WARRIOR SERIES 

USER MANUAL 

(FULL VERSION) 

 
 

SW Ver. 1.24 

 

 
 

 
 
 
 

 

 

 

Summary of Contents for WBK 165a

Page 1: ... P N 3136611513 Revision A Apr 2014 Adam Equipment Company 2014 Adam Equipment WARRIOR SERIES USER MANUAL FULL VERSION SW Ver 1 24 ...

Page 2: ... Adam Equipment Company 2014 ...

Page 3: ...14 ANIMAL DYNAMIC WEIGHING 16 7 0 USER PARAMETERS 18 CHECK WEIGHING PARAMETERS 18 PERCENT WEIGHING and ANIMAL WEIGHING 19 RS 232 PARAMETERS 20 SCALE PARAMETERS 21 8 0 BATTERY OPERATION 23 9 0 RS 232 INTERFACE 24 INPUT COMMANDS FORMAT 28 10 0 RELAY INTERFACE 29 11 0 CALIBRATION 31 12 0 SERVICE PARAMETERS 32 USING 1000 TO ENTER THE SERVICE PARAMETERS 32 USING THE SERVICE PARAMETERS 33 13 0 ERROR COD...

Page 4: ...the high limit These can work in conjunction with an audible alarm for check weighing as well as the display showing LOW OK and HI The WARRIOR is supplied with a RS 232 bi directional interface and real time clock RTC The WARRIOR has a sealed keypad with colour coded membrane switches a large easy to read liquid crystal display LCD and a green backlight Included functions are automatic zero tracki...

Page 5: ...ons Ounces Model WFK 75 WFK 165a WFK 75H WFK 165aH WFK 150 WFK 330a WLK 150 WLK 330a Maximum Capacity 75kg 165lb 75kg 165lb 150kg 330lb 150kg 330lb Readability 0 005kg 0 01lb 0 001kg 0 002lb 0 01kg 0 02lb 0 01kg 0 02lb Resolution 1 15000 1 75000 1 15000 1 15000 Repeatability Std Dev 0 01kg 0 02lb 0 002kg 0 004b 0 02kg 0 04lb 0 02kg 0 04lb Linearity 0 01kg 0 02lb 0 002kg 0 004lb 0 02kg 0 04lb 0 02k...

Page 6: ...ght or near air conditioning vents Avoid unsuitable tables The table or floor must be rigid and not vibrate Avoid unstable power sources Do not use near large users of electricity such as welding equipment or large motors Do not place near vibrating machinery Avoid high humidity that might cause condensation Avoid direct contact with water Do not spray or immerse the scales in water Avoid air move...

Page 7: ...wing angle of the Indicator to the ideal position and tighten the 2 x locking handles Level the scale by adjusting the five feet on the WSK WBK or the four feet on the WFK WLK until the bubble is in the centre of the level indicator If the scale rocks re adjust the feet NOTE Use of a food safe grease is recommended on the threaded part of the feet to keep them turning freely Attach the power input...

Page 8: ...ed when setting up a value for the Parameters Selects parts counting Used to set the sample quantities while parts counting A secondary function is of incrementing the active digit when setting a value for Parameters Selects the weighing unit to be displayed from those which are enabled See parameter S1 in section 7 4 of this manual A secondary function is to move the active flashing digit to the ...

Page 9: ... also adds the value to the accumulation memory if the accumulation function is not automatic A secondary function ESC is to return to normal operation when the scale is in a Parameter setting mode To switch the Indicator on or off The WARRIOR will store the weighing unit and the check weighing values currently in use if power is powered off These will be re called when the Indicator is next power...

Page 10: ...lay will show when a weight is below inside or above the check weighing limits Other symbols will show when a weight has been tared NET the scale is at zero and stable if a value has been stored in memory or when the animal weighing function has been enabled A battery bar symbol will show the state of charge of the internal battery ...

Page 11: ...or zero The scale has an automatic re zeroing function to account for minor drifting or accumulation of material on the platform However you may need to press the 0 T key to re zero the scale if small amounts of weight are shown when the platform is empty TARING Zero the scale by pressing the 0 T key if necessary The ZERO indicator will be ON Place a container on the platform and a value for its w...

Page 12: ...ighing divisions of the scale capacity When the container is removed a negative value will be shown If the scale was tared just before removing the container this value is the gross weight which includes the container and the entire product it contains The ZERO indicator will be on to indicate that the platform is back to the same condition as it was when zero was last set To delete a Tare value p...

Page 13: ...ale is showing weight pressing the Pcs key will start the parts counting function The scale will show P 10 asking for a sample size of 10 parts Change the sample size to the desired quantity by pressing the Pcs key It will cycle through the options 10 20 50 100 200 and back to 10 Press the 0 T key again when the number matches the number of parts used as the sample As more weight is added the disp...

Page 14: ... both as described in section 7 1 The limits can be set when the scale is in weighing or parts counting modes After limits have been set the Check weighing function is enabled When a weight is placed on the scale the LED s above the display will show if the weight is above or below the limits and the beeper will sound as described below if the beeper is enabled see section 7 1 The relay outputs ar...

Page 15: ...l show ACC 1 and then the total in memory for 2 seconds before returning to weighing The RS 232 interface will output to a printer or PC Remove the weight allowing the scale to return to zero and put a second weight on When this value is stored the display will show ACC 2 then the new total and finally the value of the second weight Repeat as necessary to add all the values needed to the memory To...

Page 16: ...nce The scale checks if the weight is too small and will show Error 7 Press Func C The first option is FunC 1 press the Func C key again display FunC 2 Press the 0 T key P1 PCt will be displayed Press 0 T again to enter percent weighing The scale will set the sample mass on the platform as 100 reference weight Remove the sample weight Then any other weight placed on the scale will be displayed as ...

Page 17: ...function then the user must manually enter the weight to be set as 100 as described below Press the 0 T key P1 PCt will be displayed Press 0 T again to enter percent weighing The scale will now accept a value the user enters as the reference weight Enter the value using the Unit key and Pcs key to select and set the value of the 100 mass When set press the 0 T key to store the value The display wi...

Page 18: ...ter animal weighing The scale will change to animal weighing and allow weighing of an unstable animal or sample on the platform To use the Animal Weighing function it is necessary to set the amount of filtering required for the item to be weighed The display will show Flt x Flt x Flt x Flt x where x is a value from 1 to 5 The higher the value the greater the amount of filter will be More active an...

Page 19: ...ghing symbol while a stable weight is determined The time it takes for the stable value will depend upon the setting of the filter parameter in the first step When a stable reading is found the display will show this value and the display will be locked until the 0 T key is pressed The display will show the Hold symbol while the display is locked To weigh a second subject press the 0 T key if nece...

Page 20: ... Esc to regress one step each time If you press Print M Esc repeatedly you will exit the User Parameter section and return to normal weighing CHECK WEIGHING PARAMETERS See section 6 5 for details of using this special weighing mode This group of parameters Set low and high limits for check weighing Enables or disables the check weighing alarm Enables or disables the negative check weighing Press t...

Page 21: ...t is within or outside the check weighing limits bP oFF Off bP inL Within limits bP otL Outside limits 20d bP inL F4 nCK This parameter enables negative check weighing function with ability to do negative tare on oFF on PERCENT WEIGHING AND ANIMAL WEIGHING See section 6 7 and 6 8 for details of using these special weighing modes Press 0 T to enter a parameter Use the Unit key and Pcs key to set th...

Page 22: ...er by pressing the Pcs key Press Print M Esc to return to the group FUnC 3 If you press Print M Esc again the scale will exit the User Parameter section and return to weighing This group of parameters can be configured by the user for setting the RS 232 active or not baud rate printing mode accumulation mode RS 232 language and user or scale ID numbers Parameter Description Options Default Values ...

Page 23: ... pressed If Print M Esc is pressed a second time only print the weight Print when Print M Esc key is pressed Do not accumulate Cont Print continuously Accumulate when Print M Esc key is pressed Print continuously Do not accumulate SCALE PARAMETERS Press 0 T to view the list of parameters Press 0 T to enter a parameter Use the Unit key and Pcs key to set the values or just the Pcs key to select the...

Page 24: ...U EL AU S3 AoF Auto Off Disable or set time increment to turn off scale SLP 0 SLP 1 SLP 5 SLP 10 SLP 0 S4 dt Set Time and Date format and settings Format for date can be changed when the display shows mmddyy ddmmyy or yymmdd by pressing the Pcs key then enter the date Enter the time manually Enter the date format and then the numeric value manually 00 00 00 mm dd yy S5 diS Display all weights or o...

Page 25: ... needs to be re charged To charge the battery simply plug the adaptor into the mains power and also into the input connector on the rear of the Indicator marked DC 12V The scale does not need to be turned on The battery should be charged for 12 hours to reach full capacity Near the display is an LED to indicate the status of battery charging When the scale is plugged into the mains power the inter...

Page 26: ...2 interface Specifications RS 232 serial interface plug As viewed from the back of the indicator 1 Pin GND Signal Ground 2 Pin RXD Received Data 3 Pin TXD Transmitted Data 4 Not connected The scale can be set to print text in English French German or Spanish See the RS 232 parameters section for details RS 232 output of weighing data ASCII code 600 19200 Baud user selectable default 9600 8 data bi...

Page 27: ... cr lf cr lf Date 12 09 2006 cr lf Time 14 56 27 cr lf cr lf Scale ID 123456 cr lf If ID is zero it is left blank User ID 234567 cr lf cr lf Net Wt 1 234 Kg cr lf Net Wt or Gross Wt cr lf cr lf cr lf cr lf cr lf cr lf Date 12 09 2006 cr lf Time 14 56 27 cr lf cr lf Scale ID 123456 cr lf User ID 234567 cr lf cr lf Net Wt 1 234 Kg cr lf Net Wt or Gross Wt Unit Wt 123 g cr lf g for metric and lb for ...

Page 28: ...d Description ENGLISH FRENCH GERMAN SPANISH Net weight Net Wt Pds Net Net Gew Pso Net Weight per unit counted Unit Wt Pds unit Gew Einh Pso Unid cr lf Date 12 09 2006 cr lf Time 14 56 27 cr lf cr lf Scale ID 123456 cr lf User ID 234567 cr lf cr lf cr lf TOTAL No 5 cr lf Wt 1 234 Kg cr lf cr lf PCS 10 pcs cr lf cr lf cr lf ST GROSS 1 234 Kg cr lf ST or US for STable or UnStable US NET 0 000 Kg cr l...

Page 29: ...eighing added to subtotals No Nb Anzhl Num Total weight and count printed Total Total Gesamt Total Print date Date Date Datum Fecha Print time Time Heure Zeit Hora Scale ID number Scale ID Bal ID Waagen ID Bal ID User ID Number User ID Util ID Nutzer ID Usuario ID ...

Page 30: ...T cr lf Tares the scale to display the net weight This is the same as pressing 0 T Z cr lf Sets the zero point for all subsequent weighing The display shows zero P cr lf Prints the results to a PC or printer using the RS 232 interface It also adds the value to the accumulation memory if the accumulation function is not set to automatic ...

Page 31: ...Pass the wires for the relays through the grommet on the rear panel The wires will connect to the PCB using the terminal strip P1 ZERO LOW OK HI COM SHIE SEN EXE EXE SIG SIG SEN 09 01 2009 AE9721 VER B RXT TXT GND BT1 C18 U5 U4 Q5 Power1 LC1 COM1 U1 P1 Relay Output Common High OK Low Zero RS 232 Interface Load Cell Input Power Connector Battery Vin no polarity Clock Battery CR1220 type The circuit...

Page 32: ...the top of the connector and insert the wire Do not exceed the safe limits of voltage or current of 24VDC or 15ma per output Depending upon the application it may be necessary to use a small relay to drive larger relays or to provide additional protection to prevent electromagnetic interference diodes as shown above to this or other machinery ...

Page 33: ... weight from platform and when the stable symbol is on press 0 T The display will show Ld then 0000XX which shows the last calibration weight used Place this calibration weight on the scale and press the 0 T key If the weight you put on the scale does not match the value displayed press the Func C key to clear the vale then use the Unit key and PCS key to set the correct value When it is correct p...

Page 34: ...ection 12 1 USING 1000 TO ENTER THE SERVICE PARAMETERS Press the 0 T key during the display counting when turned on When Pn is displayed enter the number 1000 using the Unit and Pcs keys and then press 0 T The displays will show the first parameters called F4 Int To select another parameter press the Pcs key to advance through the parameters Press the 0 T key to enter a parameter To exit a paramet...

Page 35: ...cs key to change the value and press 0 T to accept the value Press Print M esc to return to weighing F5 RE ZERO RANGE To enter this parameter press the 0 T key when F5 rEZ is shown The display will show the current re zero range Press the Pcs key to change the value Press 0 T to accept the value Press Print M esc to return to weighing F6 SUCCESSIVE TARE To enter this parameter press the 0 T key wh...

Page 36: ...ro is 30 000 90 000 approx Typical value at full capacity is 500 000 approx F8 ZERO MODE To enter this parameter press the 0 T key when F8 ZEm is shown Select the Zero mode desired In all but special cases Zero Mode 1 is used The other 2 zero modes are for unique locations in the world and effect the range of the zero Press the Pcs key to change the value Press 0 T to accept the displayed value Pr...

Page 37: ... if the current Auto Zero range Press the Pcs key to change the value Press 0 T to accept the displayed value Press Print M Esc to return to weighing Fb FPS User Function Password This parameter set a password to control access to the user functions as described in Section 7 If the password is set to 0000 the control is disable and the user has free access to the functions To enter this parameter ...

Page 38: ...r Adam Equipment for assistance Err 6 A D out of range The values from the A D converter are outside the normal range Remove the weight from the scale if overloaded Make sure the pan is fitted correctly Indicates the load cell or the electronics may be faulty If the problem persists contact your dealer or Adam Equipment for assistance Err 7 100 weight out of range Weight value set as 100 for perce...

Page 39: ...rts and accessories contact your supplier or Adam Equipment A partial list of such items is as follows Power Supply Module Replacement Battery Replacement feet Replacement screws and brackets Printer printer paper etc RS232 connector cable Replacement top pan Relay interface parts ...

Page 40: ... B Details of the unit purchased This part of information should always be available for any future correspondence We suggest you to fill in this form as soon as the unit is received and keep a print out in your record for ready reference Model name of the scale Serial number of the unit Software revision number Displayed when power is first turned on Date of Purchase Name of the supplier and plac...

Page 41: ...Page 39 ...

Page 42: ...aging and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warranty does not cover equipment where defects or poor performance is due to misuse accidental damage exposure to radioactive or corrosive materials negligence faulty installation unauthorised modifications or attempted repair or failure to observe the requirements and rec...

Page 43: ...rence when the equipment is operated in a commercial environment The equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct...

Page 44: ...s Health and Fitness Scales Retail Scales for Price computing For a complete listing of all Adam products visit our website at www adamequipment com Copyright by Adam Equipment Co All rights reserved No part of this publication may be reprinted or translated in any form or by any means without the prior permission of Adam Equipment Adam Equipment reserves the right to make changes to the technolog...