CPU ADAM 821x
Chapter 6 Deployment of the CPU 821xDP
ADAM 8000 Manual CPU 821x – Rev 1.1
6-11
To include the CPU 821xDP into a leading master system, the GSD-file
included in the package is required.
•
Start your configuration program and configure the Profibus-DP master
that will be the leader of your CPU 821xDP.
•
Add a DP slave of the station type „CPU821xDP“. This is to find in the
hardware catalog under
Profibus-DP > Additional field devices > I/O >
ADAM_CPU821xDP
.
•
Assign a valid Profibus address.
•
Assign memory space from the address area of the CPU to the Profibus
section in form of „modules“ for in- and output.
•
Save your project and transfer it into the CPU of your master system.
In the following the relevant dialog windows for the master configuration are
shown:
Note!
If your DP master system is a System 82xx module from Advantech, you
may parameterize the directly plugged-in modules by including a "DP8000"
slave system.
To enable the ADAM CPU to recognize the project as central system, you
have to assign the Profibus address 1 to your slave system!
Configuration in
the leading
DP master