CPU ADAM 821x
Chapter 4 Deployment of the CPU 821xNET
ADAM 8000 Manual CPU 821x – Rev 1.1
4-11
When the CPU 824xNET is first turned on the module has a predefined
initial Ethernet address.
This address is available from the label that has been attached to the side
of the module.
This Ethernet address is only used when the module is first turned on, to
calculate a unique IP address according to the following formula:
00 20 D5 80 2D 7D
Ethernetadresse
hex.
213.128.45.125
IP-Adresse
ADAM-spez.
dez
Note!
A relationship between the Ethernet address and the IP address only exists
when the module is turned on for the first time.
You may always use the function CP-Init in WinNCS to assign a different
address.
Attention!
The original Ethernet address may not be restored since it is not possible to
perform an overall reset of the CP section.
Initial address