background image

6

4- MONTAGE & OPERATING

Check if the STABILIZER has been subjected to any damage before unpacking it.

If you notice any damage then contact to transport firm.
Check if all the spare parts have been supplied with the STABILIZER.

Delivered pack includes:
•  Automatic Voltage Regulator
•  User Manual

By the help of rolling wheels, carry the unit to a suitable location to install it.

Plug the input power cable of STABILIZER to properly earthed mains.

Check the connections before changing the position of the input, output, and bypass
switches to suitable positions.

If there is any circuit breaker or fuse on the mains line of Automatic Voltage
Regulator, switch it to ON position. Switch the input fuse to ON position on the
STABILIZER. Switch the mechanic by-pass
            Switch to REGULATOR (2) position.

Automatic Voltage Regulator is operating now. During the start, RED signal lamp is
lighting and voltmeter is working. When the output voltage is displayed normally,

STABILIZER will start automatically.
             During this time there will be voltage on output clemens and plug.

 Connect the load to the circuit.

When the main is out of tolerance STABILIZER will STOP automatically. When the
mains return to normal limits regulator will START automatically.

Regulator will be out of circuit during the MAINS (1) position of mechanic bypass
switch. During this time there will be voltage on output clemens and plug.

In three phase regulators, automatic phase protection is available. If one of the input
phases is OFF or unstable, other 2 phases will be cut off automatically.

Summary of Contents for e-AVR series

Page 1: ...1 USER MANUAL ADAMS AVR e SERIES Uninterruptible Power Systems ...

Page 2: ...S 2 2 DESCRIPTION OF THE SYMBOLS USED IN THIS MANUAL 3 3 INTRODUCTION 4 3 1 Preliminary warnings to use the STABILIZER 4 4 MONTAGE OPERATING 5 5 MAINTENANCE CLEANING 6 6 TROUBLESHOOTING 6 7 STORAGE 6 8 TECHNICAL SPECIFICATIONS 7 ...

Page 3: ...ent section of the technical specifications table before introducing it into the circuit When installing the STABILIZER it is necessary to use a connection cable of suitable diameter The point to be noted here is that the neutral and the earthing connections should be done in the proper way Place all the cables in a proper place so that they are not stepped on or get caught into peoples feet Befor...

Page 4: ...he STABILIZER and the walls in order to maintain adequate air flow 2 Description of the symbols used in this manual The following symbols have been used in this manual This symbol gives information regarding points important for user s own health and safety STABILIZER operation and the safety of your data This symbol gives information warnings and other suggestions This symbol shows the operations...

Page 5: ...TABILIZER and the transfer of the mains to the output is done by 1 0 2 REG switches 1 Input bypass to output position 0 No voltage applied position 2 Regulator position 3 1 Preliminary warnings to use the STABILIZER Automatic Voltage Regulators STABILIZER are used to protect the sensitive loads from the unstable mains and to provide proper operating of the load Related points for human health are ...

Page 6: ...n Switch the input fuse to ON position on the STABILIZER Switch the mechanic by pass Switch to REGULATOR 2 position Automatic Voltage Regulator is operating now During the start RED signal lamp is lighting and voltmeter is working When the output voltage is displayed normally STABILIZER will start automatically During this time there will be voltage on output clemens and plug Connect the load to t...

Page 7: ...ER Ensure that the air holes are open The STABILIZER body can be wiped with a clean and dry cloth 6 TROUBLESHOOTING If any errors of faults are observed on the STABILIZER make sure you check the following points before informing the authorized technical service Does the distribution panel have mains connection Have the Input Automatic fuses blown off Informing the authorized service about the STAB...

Page 8: ...te when mist is formed Leave enough space for ventilation around the STABILIZER Front 30 cm Back 30 cm Response Speed 80 V sec Electrical Specifications Output Voltage regulation 2 Power Factor 1 Crest Factor 3 Total Harmonic Distortion THD without distortion Output frequency same with the input Noise Level Relative noise level depending on the installation site For all models 45 dB A ...

Reviews: