Turn the key on the control panel counterclockwise. The green indicator lamp will go
out.
5.3. EMERGENCY SHUTDOWN
If the following window appears on the screen:
Figure 5.2 – NetCom window
it means that connection with some parts of the system was lost was lost.
There are following reasons for that:
−
The system shutdown procedure wasn’t performed correctly;
−
Emergency button was pressed;
−
Technical problems with generator or any other parts of the system.
There are 2 buttons on it window:
−
Press RESUME if you want time to fix the problem.
−
Press SHUT DOWN if it’s emergency problem and you need to turn off the system
(ex. Emergency button was pressed.)
When this window appears, the system gives you 5 minutes (amount of time optional) to
click one of this two buttons, after that it will turn off automatically.
If you click RESUME button, AWS doesn’t turn off, until you click SHUT DOWN, it takes
you time to fix the problem. If connection with generator will be restored, this window will dis-
appear.
If you click SHUT DOWN button, the system turns off immediately.
To switch off the AWS PC, when the System is disabled, use the
standard Windows function or hold down the power button for more
than 4 seconds.