CLEARPASS
Full-Body Security Screening System
OPERATION
MANUAL
Identification
ADN190.00.00.000 OM2
Revision
1
Date
02.2022
Page
49 of 52
6.5. DISPOSAL
6.5.1. Safety Precautions
To disassemble the components of the System for purposes of disposal, you should
adhere to the following safety precautions:
1)
Switch OFF the system and disconnect the power cable.
2)
Use ONLY serviceable tools when disassembling.
6.5.2. Preparing the Equipment for Disposal
Demount the components of the System.
Remove lead protection elements, electronic units, cables and wires. Remove accumu-
lators from the UPS.
Remove electronic boards from the housings of electronic equipment (system units,
UPS, interface unit, X-ray detector, etc.).
Demount electric cables and wires from the whole equipment.
Sort the dismantled equipment into black and colored metals, precious metals and plas-
tic articles, accumulators.
6.5.3. Disposal Methods
The System equipment sorted into ferrous and non-ferrous metals and their alloys, pre-
cious metals, plastic articles and accumulators should be given to a firm authorized to collect
and recycle the relative materials.