7-4
Adaptec CI/O Management Software User’s Guide
Note:
When the spare is created, Adaptec CI/O
Management Software should automatically start a
Reconstruct operation on the array. If for some reason
the reconstruct does
not
begin automatically, follow
the remaining steps to perform it manually.
7
Click
to open the Storage Configuration window. Right-
click on the
Array
icon that looks like this
and select
Reconstruct
from the drop-down menu. If the array has one
failed drive the Scheduler dialog box appears.
If you have a RAID 0/1 array with two or more failed disks,
and at least one disk of each mirrored pair is still good, a dialog
box appears with a list of the failed drives. You must
reconstruct the disks one-at-a-time, starting over each time at
the beginning of these steps. Select one of the drives on the list
and click
OK
; the Scheduler dialog box appears. (This assumes
that you have already physically replaced all of the failed
drives with good drives.)
8
Enter the required information for the Reconstruct operation in
the Scheduler dialog box. You can select
Immediate
to
reconstruct the drive immediately or select
Schedule
to
schedule the operation for a later time. (See
Setting Scheduling
Options
on page 8-2 for more information.)
9
Select an Execution Priority -
high
,
medium
, or
low
.
10
Click
OK
.
11
At the prompt, confirm that you want to reconstruct the array
member.
12
Read the event notifications that appear in the System Monitor
window (they may also appear as pop-ups on the screen) to
determine when the reconstruct is complete.