7-8
Adaptec CI/O Management Software User’s Guide
5
Click
OK
to the drive lights from blinking.
6
You can also click on the Stop blinking lights icon
to stop
all of the drive lights from blinking.
Reactivating an Off-line Array
An array may go off-line because a cable is disconnected or because
you mistakenly removed the wrong disk while trying to replace a
failed disk. In these situations, the array shuts down temporarily.
Depending on the reason that the array went off-line, it is possible to
reactivate it and resume I/O without data loss. See
Responding to an
Off-line Array
on page 10-6 for more information.
After you correct any hardware problems, follow these steps to
reactivate an off-line array:
1
Click
to open the Storage Configuration window.
2
Right-click on the dimmed icon of the off-line array and select
Reactivate
from the drop-down list.
3
At the prompt, confirm that you want to reactivate the array.
Be sure that any hardware problems are corrected before you
do this.
Changing an Array Name
When you create an array, you assign it a name. This name appears
beneath the array icon and in many of the windows and dialog
boxes. It is also used to identify the source of event notifications. You
can change this name at a later time.
Follow these steps to change the name of an existing array:
1
Click
to open the Storage Configuration window.
2
Right-click the icon
of the array whose name you want
to change.