9-41
enclosure Commands
enclosure show temperature
To display the temperature status of a specific temperature sensor
on a specific SAF-TE enclosure management device, use the
enclosure show temperature
command. You can also use
this command to display the temperature status of all temperature
sensors on the enclosure management device or devices.
Syntax
enclosure show temperature [{enclosure}]
[{sensor}]
Parameters
{enclosure}
Specifies the ID associated with the enclosure management
device for which you want to display temperature status
information. For this version, the controller supports a
maximum of eight enclosure management devices on each
bus.
If you do not specify an ID, the command displays the
temperature status information for all enclosure management
devices connected to the controller.
{sensor}
Specifies the unit number associated with the temperature
sensor whose status you want to display. This integer can
range from 0 to 15 inclusive.
If you do not specify a unit number, the command displays
the status for all temperature sensors on the enclosure
management device or devices.
Examples
The following example displays the temperature status of
temperature sensor unit
0
on enclosure management device
0
:
AAC0>enclosure show temperature 0 0
Executing: enclosure show temperature 0 0
Enclosure Sensor Temperature Threshold Status
--------- ------ ----------- --------- --------
0 0 70 120
NORMAL
Summary of Contents for AAR-2020SA
Page 1: ...R Command Line Interface Reference Guide...
Page 107: ...3 76 container Commands container extend file_system page 3 40 container list page 3 50...
Page 170: ...4 24 controller Commands Related Commands controller commands controller details page 4 2...
Page 220: ...7 4 logfile Commands Related Commands logfile commands logfile end page 7 2...