Chapter 2: Using the Command Line Utility
●
24
Parameters
Controller# is the controller number.
Tabular creates output in tabular format.
Examples
ARCCONF GETSMARTSTATS 1
ARCCONF GETSMARTSTATS 1 TABULAR
arcconf getstatus
The GETSTATUS function displays the status of any background command that is currently
running. Including information about the most recent rebuild, synchronization, logical-drive
migration, and compaction/expansion. The information includes the type of operation, status,
logical drive number, logical drive size, and percentage of the operation completed.
Note:
1
GETSTATUS reports currently active operations for both ARCCONF commands and
commands issued from the Adaptec Storage Manager.
2
GETSTATUS reports verify, clear, initialize, and secure erase operations on physical
devices.
3
GETSTATUS only reports active operations. It does not display information if the
operation is completed.
Syntax
ARCCONF GETSTATUS <Controller#>
Parameters
Controller# is the controller number
Example
ARCCONF GETSTATUS 1
arcconf getversion
Lists version information for all controllers or a specific controller’s software components,
including information about the BIOS, driver, firmware currently running, and firmware that
will run after a reboot.
Note:
The firmware version that will run after a reboot is called the “staged” firmware.
Syntax
ARCCONF GETVERSION (use this for information on all controllers)
ARCCONF GETVERSION <Controller#> (use this for information on a specific
controller)
Parameters
Controller# is the controller number
Example
ARCCONF GETVERSION