5-10
DuraStor 6220SS/7220SS Installation and User’s Guide
Replacing the Cooling Fan Module
When a cooling fan fails
■
The Fan Status LED on the front bezel lights up solid amber.
■
The alarm sounds.
A failed cooling fan must be replaced immediately.
Note:
The cooling fan module is hot-swappable.
Warning:
Do not
operate the DuraStor 312R for longer than 5
minutes with the cooling fan module removed. Cooling is
unavailable to all components while the fan module is
removed.
1
Loosen the screw that secures the cooling fan module to the
storage enclosure. See
Figure 5-6
.
Figure 5-6. Loosening the Screw