3-38
DuraStor 6220SS/7220SS Installation and User’s Guide
Stand-Alone Dual-Port (Hubs Disabled)
The following diagram illustrates the logical connection of the
stand-alone dual-port topology with the hubs disabled.
Figure 3-33 Single Host - Hubs Disabled
Note:
Ports P3 and P4 active.
By default the controller’s operating mode is set to active-active
single-port and the internal hub is set to be
Enabled
. This topology
is for stand-alone dual-port and will need to be changed. If your
topology uses the
hubs disabled
you will need to access the OCP
menu and disable this feature.
1
Access the controller menu from the OCP and select the
appropriate controller (Controller 1 or Controller 2).
2
From the System menu, select
Configuration
then select
Option
Configuration
.
3
From the Option Configuration menu, select
Operating Mode
,
select
StandAlone Dual Port,
then press
Enter
.
P2
FC2
FC1
FC PORTS
T
T
T
T
T= Location of internal termination.
PHYSICAL
DRIVE CHANNELS
DuraStor FC RAID Appliance
Controller 1
ACTIVE
CH0
Up to 12 Disk Drives
To FC Switch
To FC Switch
CH1
CH2
CH3
CH0
CH1
CH2
CH3
P1
P3
P4
Active
Active
Up to 12 Disk Drives
Up to 12 Disk Drives
Up to 12 Disk Drives
DuraStor IUG.book Page 38 Wednesday, January 30, 2002 10:49 AM