&KDSWHU/*'78VHUV0DQXDO
//
&&KKDDQQJJH
H''UULLYYH
H11DDP
PHH
This command allows you to change the name of an Array Drive. The name serves to iden-
tify an Array Drive in GDTSETUP. This can be very helpful for configurations where several
Host Drives of various types are operated by a single controller.
//
(([[SSDDQQG
G$$UU
UUDD\
\''UULLYYHH
The
Expand Array Drive
option, which is also available online within GDTMON, includes two
functions:
1.
Migration
of the RAID level of a given Array Drive
RAID 0 -> RAID 4 and vice versa
RAID 0 -> RAID 5 and vice versa
2.
Expansion
of the capacity of a given Array Drive
To initiate a migration or expansion with a RAID 4/5 Array Drive, the state must be
ready
.
The data on the Array Drive remain intact and are not affected by the expansion.
The additional capacity is introduced as new Host Drive (see next pages).
If a Logical Drive fails during the expansion, the expansion process continues until the ex-
pansion is finished. The Array Drive changes into the
fail
state.
In the following example the capacity of a given 400MB RAID 5 Array Drive is expanded.