In the gxsd.dat file:
In the gxsd.dat file, add the following:
<ctrl>
<screen_standby value="X"/>
</ctrl>
This is to be pasted anywhere into the <pr> section. The value "X" has to be a decimal value in seconds.
The OLED screen fades after the specified time has passed. After the fade out and an additional 10
seconds the OLED screen turns off.
However, if you modify the gxsd.dat file as mentioned, the setting will be default which will be reflected
in the application as well. This only needs to set once in the gxsd.dat file.
This method is currently available only in USB mode.
By default, a 10-second period is between the fade out and the off state.
This setting only goes live after the scanner is connected in the application. If the scanner is
turned on, but it is not connected in the application, the OLED display does not enter sleep
mode. However, after connecting the scanner in the app, the setting goes live and the display
enters sleep mode after the time specified.