Replacing the Billboard UPS

(PN 1109502801SP)

The billboard UPS (Uninterruptible Power Supply) is a 1500VA (Volt Amp) rack mounted 
intelligent UPS that prevents data loss, downtime, and equipment damage due to power 
outages, voltage fluctuations, and transient surges. The UPS resides inside the deluxe 
remote control cabinet and provides back up power for a limited time to all the components 
plugged into it.

The UPS software and SNMP / Web card allows billboard operators to remotely monitor 
control cabinet equipment plugged into the UPS. Power can be cycled on and off on two sets 
of UPS receptacles (load 1 and 2) allowing for a remote reboot of critical components. 
Another feature of the UPS is the capability to view the control cabinet’s ambient 
temperature / humidity logs.

Figure 1: Front view of billboard UPS.

Before you begin

Kit contents

Tools / Safety equipment needed

„

Full body safety harness with lanyard

„

#2 Phillips screwdriver

Part Number

Qty

Description

1109502801

1

1500VA rack mounted UPS.

11099001

1

SNMP / Web card (factory installed).

Mounting brackets

2

Mounting brackets and screws used to mount the UPS in the cabinet.

1109610110

1

Instructions

Summary of Contents for Tripp-Lite 1109502801

Page 1: ...t surges The UPS resides inside the deluxe remote control cabinet and provides back up power for a limited time to all the components plugged into it The UPS software and SNMP Web card allows billboard operators to remotely monitor control cabinet equipment plugged into the UPS Power can be cycled on and off on two sets of UPS receptacles load 1 and 2 allowing for a remote reboot of critical compo...

Page 2: ... doors on the control cabinet If applicable remove the control cabinet s padlock Turn cabinet handle and pull open the control cabinet door 3 Disconnect all cables from the back of the UPS Note Single billboard configurations have fewer cables plugged into the UPS Figure 2 Rear view of a dual billboard UPS configuration WARNING Possible fall hazard When servicing billboard components service perso...

Page 3: ...t force the shelf all the way out otherwise power adapters tie wrapped to the shelf may become disconnected from their components Figure 4 UPS removal Remove the UPS from the control cabinet 5 Attach mounting brackets to both sides of the replacement UPS Figure 5 UPS mounting brackets 6 Set the replacement UPS on the sliding shelf and slide it into the control cabinet 7 With the previously removed...

Page 4: ...components on dual billboard configurations only that may require power to be cycled on or off from a remote Internet connection Item Port Component connection A Load 1 2 switched outlets PC controller 1 power cord label ID 17 DVI fiber converter 1 power cord label ID 8 B Load 2 2 switched outlets PC controller 2 power cord label ID 22 DVI fiber converter 2 power cord label ID 9 C Load 3 4 unswitc...

Page 5: ...ed UPS information A B D E C Item LED Normal indicating status A Power Continuous green LED B Voltage correction Green LED is either continuous blinking or not lit at all The UPS will also emit a slight clicking noise during voltage correction C Output load level Continuous green or yellow LED D Battery charge Continuous green LED full battery charge yellow LED half battery charge or red beginning...

Page 6: ...THIS PAGE INTENTIONALLY BLANK REPLACING THE BILLBOARD UPS 6 ...

Reviews: