USER’S MANUAL V-line 899x.xxx/LPG
13
even in case the nozzle has been either hung up again without fuel dispensing or previous transaction has
not been deactivated by means of RLS entry.
8.1.
Manual setting of unit prices
Necessary conditions for the transition to the setting of unit prices
– MAN mode of operation
– the nozzle has not been lifted since the last activation of the counter
– transaction executed shall be acknowledged (deactivation by means of RLS entries).
In the MAN mode the unit prices of fuel product are set by means of the KL-MANINF manager keyboard or
the KL-SERINF service keyboard.
1.
The user can enter the setting mode of unit prices by depressing the „0― key.
2.
In the setting mode of unit prices
-
the number of side for which the unit price is being set ("1" ... A side, "2" ... B side) is displayed
on the first line of displays (i.e. on the line of total price)
-
the number of nozzle for which the unit price is being set is displayed on the second line of
displays (i.e. the line of total volume)
-
on the third line of displays the digit, the value of which is being set by the user, is flashing (e.g.
on the line of unit price)
3.
The user
-
raises the numerical value of the digit actually set by the "+" key(i.e. the flashing one), (digit 9
passes into 0), by depressing the "+" key we can list through 0-9 values - i.e. the autorepeat
function
-
shifts the digit setting to higher digit positions by means of the "-" key
-
shifts the setting from the highest position of the product unit price to the lowest digit position
of the product unit price of the next nozzle by means of the "-" key
4.
In this way the user can set successively the price values for all nozzles on the A side, then B side (if
it exists and the products on this side differ in price).
5.
Whenever the user can terminate the setting of the unit price values by depressing the „0― key.
6.
Now the unit price values have been written in non-volatile storage in this way and the counter sets
the MAN mode.
8.2.
Setting of unit price values from the control system in AUTO mode
In AUTO mode the unit price values are set from the control system for all transactions independently on
unit price values set for the MAN mode.
The unit price values for the AUTO mode are set for all dispensing points by dynamic statement
(command) "permission to dispense" transmitted from the filling station console or by the "price setting"
statement. All these statements are a part of the specification of the EASYCALL communication protocol.
8.3.
Displaying procedure of electronic totalizers for dispensers fitted with
ADP1/T, ADP2/T, ADP1/L electronic counter
The ADP1/T, ADP2/T, ADP1/L counter is fitted with non-resettle electronic totalizers of volume and price
for individual dispensing nozzles.
The totalizers can be displayed on the displays of the side by means of the KL-MANINF manager keyboard.
The display of the totalizer can be switched by lifting the relevant nozzle or by switching the LPG switch.
The sum of the volume (or the sum of the price) is displayed on the displays of the side on the coupled
lines of the total price and total volume. Both displays of the side display an identical sum, as the first
from the left "U" character is displayed on the total price line for the display of the volume sum and
"A" character for the display of the price sum.
The second character from the left displays the highest digit position of the relevant sum, the sixth
character from the left displays the lowest digit position of the relevant sum.
The side number and the nozzle number of the totalizer displayed at this moment are displayed on the
unit price line:
e.g..: 1 - 1...A side - nozzle No. 1;
2 - 1...B side - nozzle No. 1.
Display procedure: