4.0 Modes of Operation
Only qualified ADB Safegate personnel select modes of operations. There are 3 ways to handle the ACE2 operation:
1. L-827 stand-alone (external to the CCR).
2. L829 stand-alone (integrated with the CCR).
3. L-890 ALCMS.
4.1 Stand-Alone Configuration
The ACE2 is only set up for stand-alone operation by qualified ADB Safegate personnel. In this mode, configuration of the
ACE2 is performed through the local menu and alternative functions of the buttons listed in
1. Modify, execute (Output Monitoring button).
2. Go to the next item (Auxiliary Monitoring button).
3. Enter, exit (Select/Config button).
4. No Function (Software Version button).
Figure 6: Functional Buttons
The stand-alone mode configuration menu is presented in
Table 2: ACE2 Stand-Alone Configuration Short Reference
Button Action
2 ↓ , 3
2 ↓ , 3 ←, 1
modify
Menu Item
Parameter
Possible value
Description
CCR Config
Menu
CCR Type
Generic, Heavy
Duty
Heavy Duty is an older brand name, which requires an additional output line
(B1, B10) to turn on and off the regulator. If this regulator is not in use adjust
setting to Generic.
CCR Class
6.6A, 20A
ADB Safegate sells two regulator output types. 6.6A and 20A output. Based on
the regulator choose the correct current output.
CCR Style
3 steps, 5 steps
ADB Safegate sells two regulator step types, 5 step and 3 step. Based on the
regulator choose the correct Step Configuration.
Line Frequency
50Hz, 60Hz
Depending on the location, the input voltage frequency may be 50Hz or 60Hz.
Set the ACE2 to the correct frequency for the area.
Ramp Interval
0.5s, 1s, 2s, 5s
When adjusting the steps of a regulator it is necessary to have a slight delay
between steps. The Ramp Interval sets the amount of time the regulator stays
at a step before moving on to the next step.
96A0357, Rev. G, 2019/11/08
13
Copyright
©
ADB Safegate, All Rights Reserved
Summary of Contents for ACE2
Page 1: ...Advanced Control Equipment ACE2 User Manual 96A0357 Rev G 2019 11 08 ...
Page 2: ......
Page 18: ...Advanced Control Equipment ACE2 Introduction 12 Copyright ADB Safegate All Rights Reserved ...
Page 42: ...Advanced Control Equipment ACE2 Parts 36 Copyright ADB Safegate All Rights Reserved ...