Physical equipment
order
Binary address
Physical equipment
order
Binary address
Physical equipment
order
Binary address
06
011000
14
011100
22
111010
07
111000
15
111100
08
000100
16
000010
1. Set the first 6 dip-switches of the dip-switch bank SW2 of each FCU PCB. The illustration shows an example for the logical
address 03: 110000.
2. Set the addresses in a logical order so that the first equipment is the one that is the furthest away from the runway.
Note
First contact ADB if you want to change this logical order.
Example for a flashing system with both FCU-1 and FCU-3 units.
Note
The example shows a non-existing set of 10 flasher heads. A normal flashing system contains 2, 21, 23, 30 or 32
flasher heads. The example only shows the logical order to number.
Equipment cabinet
Dip-switch SW2 set to:
A: furthest away from the runway
Equipment 01 = 100000
Equipment 02 = 010000
Equipment 03 = 110000
B
Equipment 04 = 001000
C
Equipment 05 = 101000
Flashing System Maintenance
Commissioning
20
Copyright
©
ADB Safegate, All Rights Reserved
Summary of Contents for FCU-1-in-1
Page 2: ......
Page 8: ...Flashing System Maintenance TABLE OF CONTENTS viii Copyright ADB Safegate All Rights Reserved ...
Page 18: ...Flashing System Maintenance Safety 8 Copyright ADB Safegate All Rights Reserved ...
Page 28: ...Flashing System Maintenance Introduction 18 Copyright ADB Safegate All Rights Reserved ...
Page 42: ...Flashing System Maintenance Commissioning 32 Copyright ADB Safegate All Rights Reserved ...
Page 64: ...Flashing System Maintenance Maintenance 54 Copyright ADB Safegate All Rights Reserved ...
Page 106: ...Flashing System Maintenance Technical data 96 Copyright ADB Safegate All Rights Reserved ...
Page 110: ......