7. Connect the input wires PH and N to the input connector of the new module.
8. Connect the wires to the DC distribution connector (D):
•
Brown: +15 V;
•
Red: +5 V;
•
Black: GND;
•
White -15 V.
9. Connect the earth connection.
10. Install the new DC power supply module (A).
11. Install the two screws (B). Use a long screwdriver.
12. Close the cabinet door.
DC power supply, fuse
13. Make sure that all power to the equipment is OFF. See §
Prepare: Switch OFF power supply
14. Remove the DC power supply module. See the procedure above.
15. Remove the two screws (A).
16. Remove the cover (B).
17. Remove the fuse (C). The fuse has a clip-on connection.
18. Install the a new fuse (C). Make sure that the type is applicable for the module.
19. Install the cover (B).
20. Install the two screws (A).
21. Close the cabinet door.