Disconnect - 2
5. Remove the Local bus connection board (A). See §
6. Remove the terminal stopper (B).
7. Remove the two screws (D) .
8. Remove the rail (C).
9. Disconnect the cables:
•
Fuses F1 and F2 (7 cables) (E);
•
Heater (cut the two soldered connections) (F);
Replace
10. Remove the wiring assembly.
11. Install the new wiring assembly. Maintenance
Connect - 1
12. Connect the seven cables of the fuses F1 and F2.
Connect heater cables
13. Slide thermo-retractable insulation sleeves on the cables;
14. Solder one cable on the connection point (A) on both sides of the heater;
UM-4019_AM02-620e, Rev. 3.0, 2020/05/12
47